DYMIND DH-36 Hematology Analyzer :-Features:3-part differentiation, 21 parametersOnly 9ul sampling volumeUp to 60 samples per hour50, 000 sample results, including parameter, histogram, and patient informationVenous whole blood, anticoagulant peripheral whole blood and pre-diluted bloodTechnical Specifications:PrinciplesElectrical impedance method (WBC/RBC/PLT) and cyanide free (HGB) methodPulse baseline tracking technology, waveform discrimination technology, digital sheath flow technology and intelligent floating threshold technologyDual-channel is used for countingParametersWBC, Lym%, Mid#, Gran#, Lym%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, PCT, P-LCC , P-LCR, 3 histograms, alarm for abnormal erythrocytes, leukocyte, and plateletThroughputUp to 60 samples per hourSample VolumeMinimum volume 9 ulCBC Analyzer Dealer PerformanceCarryover Repeatability LinearityWBC ≤0.5% ≤2.0% (7-15×109/L) 0.00-300×109/LRBC ≤0.5% ≤1.5% (3.5-6.0×1012/L) 0.00-8.5×1012/LHGB ≤0.5% ≤1.5% (110-180g/L) 0-250g/LPLT ≤1.0% ≤4.0% (150-500×109/L) 0.00-3000×109/LData Storage CapacityUp to 50, 000 results including parameter, histogram, and patient informationCBC Analyzer In RajasthanCommunicationFour USB ports and Bi-directional LIS connectionHematology Analyzer in JaipurOperating EnvironmentTemperature: 15oC-30oCHumidity: 30-85%Air Pressure: 70-106 kPa Power RequirementA.C. 100-240V ≤300VA 50/60Hz Dimension and Weight410mm(L) × 353mm(W) × 471mm(H)Weight: 25kgHematology Analyzer Dealer In Jaipur Hematology Analyzer In Rajasthan CBC Analyzer In Jaipur CBC Analyzer In India Hematology Reagents
Send Enquiry
Read More
DYMIND DH-76 Auto Hematology Analyzer:Features: + 5-part differentiation, 29 parameters, 1 3D scatter gram , 3 2D scatter grams and 3 histograms +Tri- angle semi-conductor Laser scatter combined with chemical dye method, advanced flow cytometry + Compact, powerful and affordable + Only 20ul sampling volume + Up to 80 samples per hour + 3 counting modes: whole blood , capillary blood and prediluted + Capability to flag abnormal samples + Large storage capacity: up to 100, 000 samplesTechnical Specifications: Principles:+Impedance method for WBC, RBC, PLT counting+Cyanide-free reagent for Hemoglobin test+Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical dye method, independent Basophil channel Parameters:WBC, Lym%, Lym#, Mon%, Mon#, Neu%, Neu#, Eos%, Eos#, Bas%, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, PCT, and 4 research parameters P-LCC , P-LCR, LIC%, LIC#, ALY%, ALY#1 3D and 3 2D 3 scatter grams and 3 histograms Throughput:Up to 80 samples per hour Sample Volume:+Whole Blood: 20ul+Prediluted: 20ul Test Mode:+CBC CBC+DIFF Performance:Carryover Repeatability LinearityWBC ≤0.5% ≤2.0% (4-15×109/L) 0.00-300×109/LRBC ≤0.5% ≤1.5% (3.5-6.0×1012/L) 0.00-8.5×1012/LHGB ≤0.6% ≤1.5% (110-180g/L) 0-250g/LPLT ≤1.0% ≤4.0% (150-500×109/L) 0.00-3000×109/L Data Storage Capacity:Up to 100, 000 results including numeric and graphical information Communication:+LAN port supports HL7 protocol+Operating Environment+Temperature: 15oC-30oC+Humidity: 30-85%+Air Pressure: 70-106 kPa Power Requirement:A.C. 100-240V ≤300VA 50/60Hz Dimension and Weight+620mm(L) × 620mm(W) × 535mm(H)+Weight: 56kgHematology Analyzer (CBC Analyzer) Dealer In RajasthanHematology Analyzer (CBC Analyzer) Dealer In Jaipur
Send Enquiry
Read More
Elisa Kit Vitamin B12PRINCIPLE OF THE ASSAYThis assay employs the direct competitive inhibition enzyme immunoassay technique. Antibody specific for VB12 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells with biotin-conjugated VB12. A competitive inhibition reaction is launched between VB12 (Standards or samples) and biotin-conjugated VB12 with the pre-coated VB12 antibody. After washing, avidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound reagent, a substrate solution is added to the wells and color develops in opposite to the amount of VB12 bound in the initial step. The color development is stopped and the intensity of the color is measured.DETECTION RANGE1.56 pg/ml-90 pg/ml.SENSITIVITYThe minimum detectable dose of human VB12 is typically less than 1.498 pg/ml.The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest human VB12 concentration that could be differentiated from zero. It was determined the mean O.D value of 20 replicates of the zero standard added by their three standard deviations.SPECIFICITYThis assay has high sensitivity and excellent specificity for detection of humanVB12. No significant cross-reactivity or interference between human VB12 and analogues was observed.Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between human VB12 and all the analogues, therefore, cross reaction may still exist.OTHER SUPPLIES REQUIRED Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm. An incubator which can provide stable incubation conditions up to 37°C±0.5°C. Squirt bottle, manifold dispenser, or automated microplate washer. Absorbent paper for blotting the microtiter plate. 100ml and 500ml graduated cylinders. Deionized or distilled water. Pipettes and pipette tips. Test tubes for dilution.PRECAUTIONSThe Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.SAMPLE COLLECTION AND STORAGE Serum Use a serum separator tube (SST) and allow samples to clot for two hours at room temperature or overnight at 4°C before centrifugation for 15 minutes at 1000 ×g. Remove serum and assay immediately or aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw cycles. Plasma Collect plasma using EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 ×g at 2-8°C within 30 minutes of collection. Assay immediately or aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw cycles.
Send Enquiry
Read More
Page 1 1