Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

RAJBIOSISPVTLTD 57f353489ec66821d8f93788 Products https://www.rajbiosis.in
{ "products": [ { "_id": "659b87389bb0be169c7f786f", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "ADVIA 2400 Clinical Chemistry Analyser System", "description": "ADVIA 2400 Chemistry System The right balance of speed and efficiency \nThe ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers:\nHigh throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads\nRapid, consistent, 2-second cycle time for faster tube speed and test throughput\nUser-defined automatic repeat, dilution, and reflex testing\nLarge onboard reagent capacity and optional concentrated reagents help to minimize intervention demands\nRefrigerated onboard storage of controls and reagents for extended stability and increased productivity\nAutomation-ready design: no additional hardware required\nFeatures & Benefits\nThe ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing.\n\nThe ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories \n\nSuperior Speed and Productivity\n\nThroughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads\nRapid, consistent, 2-second cycle time\nThroughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample\nAutomatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing\nAutomation-ready\n\nPoint-in-space aspiration enables connectivity to a track.\nRedundant sample loading provides built-in backup and easy handling of non-routine samples.\nDirect sampling from track prevents tubes being detained at an analyzer and reduces aliquoting.\nMinimal Need for Operator Intervention\n\nMinimal-maintenance ISEs\nLarge onboard reagent capacity and optional concentrated reagents for fewer interruptions\nNo-maintenance, 37°C incubation oil bath\nAuto-calibration and auto-QC from refrigerated onboard calibrators and controls\nMicrovolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity.\nRemote diagnostics and Inter-Laboratory Quality Control (ILQC) options\nExceptional Reliability\n\nSample integrity check for icterus, hemolysis, and lipemia\nSample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection\nAdvances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity", "price": 445000.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "TDM", "DAT", "menu", "hour", "HbA1c", "track", "backup", "600 ISE", "methods", "general", "auto-QC", "icterus", "lipemia", "Benefits", "Features", "controls", "dilution", "analyzer", "Advances", "reduction", "200 tubes", "hemolysis", "cystatin C", "2400 tests", "to 60 days", "aliquoting", "efficiency", "calibrators", "Minimal Need", "32,000 tests", "Sample probe", "connectivity", "ILQC) options", "right balance", "interferences", "abuse testing", "walkaway time", "easy handling", "00 photometric", "reflex testing", "Superior Speed", "assay linearity", "Direct sampling", "test throughput", "routine samples", "routine testing", "three ISE tests", "turnaround time", "onboard storage", "High throughput", "heavy workloads", "Auto-calibration", "crash protection", "maximum capacity", "space aspiration", "reagent stability", "faster tube speed", "therapeutic drugs", "heaviest workloads", "Remote diagnostics", "CardioPhase® hsCRP", "extended stability", "additional hardware", "productivity levels", "fewer interruptions", "demanding workloads", "intervention demands", "liquid-level sensing", "calibration frequency", "Operator Intervention", "specialty chemistries", "Sample integrity check", "nine photometric tests", "Interesting new assays", "Microvolume technology", "short-sample detection", "Exceptional Reliability", "Automation-ready design", "Minimal-maintenance ISEs", "high-volume laboratories", "37°C incubation oil bath", "Redundant sample loading", "high turnaround-time goals", "therapeutic drug monitoring", "specific protein measurement", "automated sample pretreatment", "User-defined automatic repeat", "automatic clot/clog detection", "efficient automation-readiness", "Large onboard reagent capacity", "optional concentrated reagents", "The ADVIA 2400 Chemistry System", "Inter-Laboratory Quality Control", "high turnaround-time (TAT) goals", "rapid, 2-second probe cycle time", "Automatic Sample Retain technology", "Rapid, consistent, 2-second cycle time", "The ADVIA 2400 Clinical Chemistry System", "The ADVIA® 2400 Clinical Chemistry System", "ADVIA 2400 Clinical Chemistry Analyser System" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 103, "imageuri": "https://productimages.withfloats.com/actual/659b8739a60e6e828d30e024.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/659b8739a60e6e828d30e024.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-01-08T05:25:12.036Z", "updatedon": "2024-01-08T05:25:12.036Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN/products/advia-2400-clinical-chemistry-analyser-system/103", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Siemens", "category": "Clinical Chemistry", "tags": [ "#ClinicalChemistry", "#LabTests", "#DiagnosticTesting", "#MedicalTechnology", "#ClinicalAnalysis", "#HealthcareTech", "#DiagnosticChemistry", "#LaboratoryScience", "#ClinicalLaboratory", "#HealthTech", "#BiochemicalAnalysis", "#ChemicalTests", "#Biochemistry", "#ClinicalDiagnosis", "#MedicalLaboratory" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "657aac1c665e3e1e4c41a9c4", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Getein 1100", "description": "Getein 1100 Immunofluorescence Analyzer:-\nDescription:-\nGetein 1100 is used to measure the concentration of biomarkers in human whole blood, serum, plasma, urine, nasal swab, or saliva samples. The results can be used as an aid in clinical diagnostics of laboratory. \n\nGetein1100 Immunofluorescence Quantitative Analyzer is an advanced on-site diagnostic analyzer, intended to deliver accurate testing results in minutes just from 3-4 drops of human specimens.\n\nTest Items Cardiac Marker —— cTnI, NT-proBNP, D-Dimer, CK-MB, NT-proBNP/cTnI, CK-MB/cTnI/Myo, H-FABP Renal Function —— CysC, mAlb, NGAL, β2-MG Inflammation Monitoring —— hs-CRP+CRP, PCT Diabetes —— HbA1c Fertility —— HCG+β Hormone ——\n\nTSH Assay Method : Lateral Flow Chromatograpgy (Immunofluorescence)\n\nTest Result :Quantitative Language\n\n\nPerformance Characterstics:\n\nPortable design\n\nEasy to use\n\nMultiplex test items\n\nLIS and HIS connectivity", "price": 54000.0, "discountamount": 2000.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "LIS", "aid", "cTnI", "mAlb", "CysC", "NGAL", "urine", "serum", "CK-MB", "proBNP", "plasma", "CRP+CRP", "minutes", "D-Dimer", "3-4 drops", "nasal swab", "laboratory", "biomarkers", "Description", "Test Result", "PCT Diabetes", "HCG+β Hormone", "concentration", "saliva samples", "Cardiac Marker", "HbA1c Fertility", "Portable design", "human specimens", "TSH Assay Method", "HIS connectivity", "human whole blood", "clinical diagnostics", "Multiplex test items", "Quantitative Language", "H-FABP Renal Function", "accurate testing results", "site diagnostic analyzer", "Performance Characterstics", "Lateral Flow Chromatograpgy", "β2-MG Inflammation Monitoring", "Getein1100 Immunofluorescence Quantitative Analyzer" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 31, "imageuri": "https://productimages.withfloats.com/actual/657aac33e71b74662970401e.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/657aac33e71b74662970401e.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2023-12-14T07:17:48.147Z", "updatedon": "2023-12-14T07:17:48.147Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//getein-1100/31", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Getein", "category": " Immunofluorescence Quantitative Analyzer", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "662ce91d49be7218fcf50be3", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Wondfo Finecare Vitamin D Rapid Quantitative Test", "description": "INTENDED USE\nThe Finecare™ Vitamin D Rapid Quantitative Test along with Finecare™ FIA Meter is a fluorescence immunoassay quantitative determination of total 25(OH) D2/D3 level in human serum or plasma. Results are to be used in conjunction with other clinical and laboratory data to assist the clinician in the assessment of vitamin D sufficiency.\nSTORAGE AND STABILITY\n1. Store at 4°C~30°C up to the expiration date.\n2. The solid marker bottle can be stored at 2°C~8°C for 28 days after being reconstituted.\n3. Do not remove the device from the pouch until ready to use. The Test Cartridges should be used within 1 hour once opened.", "price": 5500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "4°", "2°C", "pouch", "device", "1 hour", "plasma", "28 days", "STORAGE", "Results", "STABILITY", "clinician", "assessment", "human serum", "conjunction", "INTENDED USE", "other clinical", "expiration date", "laboratory data", "solid marker bottle", "Finecare™ FIA Meter", "The Test Cartridges", "vitamin D sufficiency", "total 25(OH) D2/D3 level", "The Finecare™ Vitamin D Rapid Quantitative Test", "Wondfo Finecare Vitamin D Rapid Quantitative Test", "fluorescence immunoassay quantitative determination" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 334, "imageuri": "https://productimages.withfloats.com/actual/662ce91f4a71d04d7050ebe2.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/662ce91f4a71d04d7050ebe2.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-04-27T12:01:33.138Z", "updatedon": "2024-04-27T12:01:33.138Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//wondfo-finecare-vitamin-d-rapid-quantitative-test/334", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Wondfo", "category": "immunoassay reagent", "tags": [ "#Immunoassay", "#Reagents", "#Biotechnology", "#LifeScience", "#Biochemistry", "#Research", "#LabLife", "#Science", "#AssayDevelopment", "#Antibodies", "#Proteins", "#DiagnosticTesting", "#ClinicalChemistry", "#Laboratory", "#MedicalResearch", "#Healthcare", "#ELISA", "#Fluorescence", "#Chemiluminescence", "#Immunology", "#MolecularBiology", "#CellBiology", "#AnalyticalChemistry", "#Microbiology", "#BiomedicalScience", "#Diagnostics", "#Innovation", "#Technology", "#PrecisionMedicine", "#Biopharmaceuticals", "#BiomedicalResearch", "#Bioreagents", "#Pathology", "#Immunodiagnosis", "#Antigen", "#AntibodyDetection", "#ResearchAndDevelopment", "#ClinicalTrials", "#HealthTech", "#Biomarkers", "#MedicalDevices", "#PrecisionHealth", "#BiomedicalEngineering", "#Therapeutics", "#Pharmaceuticals", "#DrugDiscovery", "#Genomics", "#Virology", "#Microarray", "#PCR", "#FlowCytometry", "#Biosensors", "#Nanotechnology", "#Immunochemistry", "#MedicalDevices", "#MedicalTechnology", "#HealthInnovation", "#BiotechStartup", "#HealthTechInnovation", "#MedicalInnovation", "#HealthScience", "#BiomedicalDevices", "#HealthcareTechnology", "#LabResearch", "#Bioassay", "#Bioinformatics", "#ClinicalLaboratory", "#AssayKit", "#PointOfCare", "#LaboratoryMedicine", "#DiagnosticKits", "#Chemistry", "#BiomedicalDiagnosis", "#BiochemicalAnalysis", "#Immunodiagnostics", "#InfectiousDiseases", "#BiomedicalTechnology", "#DiagnosticInstruments", "#HealthcareInnovation", "#MolecularDiagnostics", "#MedicalInstruments", "#InVitroDiagnostics", "#BiomedicalInnovation", "#ClinicalChemistry", "#BiomedicalTesting", "#BiomedicalDevices", "#HealthcareTechnology", "#DiagnosticSolutions", "#BiomedicalSolutions", "#LabEquipment", "#HealthcareDevices", "#BiomedicalDevices", "#DiagnosticDevices", "#MedicalDevices", "#BiomedicalTools", "#LabTools", "#ResearchTools", "#LabSupplies", "#LaboratoryEquipment", "#ResearchEquipment", "" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "662b694c9215811ea48df996", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Meril RNA Extraction Kit - Column Based", "description": "RNA Extraction Kit - Column Based\nProduct Overview\nRNA extraction kit is used to isolate the nucleic acid (RNA) from virus in bio fluid and transport media samples for clinical in-vitro diagnostics applications.\n\nApproved by ICMR\nRNA kit components can be stored at room temperature (15-30°C) for one year\nPack-size of 20 tests, 50 tests & 250 tests", "price": 850.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "ICMR", "virus", "one year", "20 tests", "50 tests", "bio fluid", "Pack-size", "clinical in", "nucleic acid", "media samples", "room temperature", "RNA kit components", "Meril RNA Extraction Kit", "Column Based Product Overview", "vitro diagnostics applications" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 237, "imageuri": "https://productimages.withfloats.com/actual/662b694e2c1b2858508ae5dd.png", "tileimageuri": "https://productimages.withfloats.com/tile/662b694e2c1b2858508ae5dd.png", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-04-26T08:43:56.559Z", "updatedon": "2024-04-26T08:43:56.559Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//meril-rna-extraction-kit-column-based/237", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Meril", "category": "Rapid Test", "tags": [ "#RapidTestKit", "#TestKitResults", "#HealthCheckup #DiagnosticTesting", "#QuickTesting", "#TestKitResultsMatter #HealthScreening", "#HealthCheck", "#QuickHealthScreening #MedicalTesting", "#MedicalDiagnosis", "#MedicalDiagnosisTools #QuickDiagnosis", "#DiagnosticSolutions", "#PointOfCareSolutions #PointOfCareTesting", "#HealthWellness", "#InnovativeTesting #HealthcareTech", "#RapidDetection", "#HealthAwareness #MedicalDevices", "#LabTech", "#RapidScreening #RapidResults", "#HealthcareInnovation", "#MedicalDevicesTech #DiagnosticInnovation", "#TestAccuracy", "#DiagnosticAccuracy #TestKitTechnology", "#MedicalScreening", "#HealthWellnessKit #HealthTech", "#RapidResponse", "#RapidHealthCheck #LabTesting", "#HomeTesting", "#AtHomeDiagnostics #MedicalDetection", "#MedicalDevices", "#MedicalInnovation #QuickResults", "#InnovativeDiagnosis", "#HealthcareInsights #AtHomeTesting", "#DiagnosticAdvancements", "#TestingAdvancements" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "662b6501a04af9164c2b0584", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Meril COVID-19 VTM", "description": "Product Overview\nMeril Viral Transport Medium is used for collection, transportation and preservation of human nasopharyngeal or oropharyngeal virus samples from the collection site to the testing laboratory.\n\nApproved by ICMR\nBest suited for the transportation of viruses in an active form\nMaintains the virulence and viability of the viral sample\nContains protective protein, antibiotics and buffers\nProvide appropriate transport and storage environment for swab samples\nContains a cryoprotectant for preservation (frozen) for prolonged storage", "price": 2500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "ICMR", "frozen", "buffers", "viruses", "viability", "virulence", "antibiotics", "active form", "viral sample", "swab samples", "preservation", "cryoprotectant", "transportation", "collection site", "prolonged storage", "protective protein", "testing laboratory", "storage environment", "human nasopharyngeal", "appropriate transport", "oropharyngeal virus samples", "Meril Viral Transport Medium", "Meril COVID-19 VTM Product Overview" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 234, "imageuri": "https://productimages.withfloats.com/actual/662b6505670596731f8d2c0e.png", "tileimageuri": "https://productimages.withfloats.com/tile/662b6505670596731f8d2c0e.png", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-04-26T08:25:37.178Z", "updatedon": "2024-04-26T08:25:37.178Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//meril-covid-19-vtm/234", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Meril", "category": "Rapid Test", "tags": [ "#RapidTestKit", "#TestKitResults", "#HealthCheckup #DiagnosticTesting", "#QuickTesting", "#TestKitResultsMatter #HealthScreening", "#HealthCheck", "#QuickHealthScreening #MedicalTesting", "#MedicalDiagnosis", "#MedicalDiagnosisTools #QuickDiagnosis", "#DiagnosticSolutions", "#PointOfCareSolutions #PointOfCareTesting", "#HealthWellness", "#InnovativeTesting #HealthcareTech", "#RapidDetection", "#HealthAwareness #MedicalDevices", "#LabTech", "#RapidScreening #RapidResults", "#HealthcareInnovation", "#MedicalDevicesTech #DiagnosticInnovation", "#TestAccuracy", "#DiagnosticAccuracy #TestKitTechnology", "#MedicalScreening", "#HealthWellnessKit #HealthTech", "#RapidResponse", "#RapidHealthCheck #LabTesting", "#HomeTesting", "#AtHomeDiagnostics #MedicalDetection", "#MedicalDevices", "#MedicalInnovation #QuickResults", "#InnovativeDiagnosis", "#HealthcareInsights #AtHomeTesting", "#DiagnosticAdvancements", "#TestingAdvancements" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "661637786e1b321fd07bbd72", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "I Chroma Boditech hsCRP", "description": "hsCRP\nHelping prognosis the occurrence of heart disease, cardiovascular disease, and stroke\n\nhsCRP is a test for testing the low level of CRP. Significantly high CRP levels are most likely a sign of a serious underlying medical condition. The most common cause is a severe infection, but there are other specific causes leading to a high CRP level. This test measures the level of CRP in 3 minutes.", "price": 6200.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "test", "sign", "stroke", "low level", "prognosis", "3 minutes", "occurrence", "common cause", "heart disease", "high CRP levels", "severe infection", "other specific causes", "cardiovascular disease", "I Chroma Boditech hsCRP hsCRP", "serious underlying medical condition" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 181, "imageuri": "https://productimages.withfloats.com/actual/6616377cdf392bde2237733c.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/6616377cdf392bde2237733c.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-04-10T06:53:44.98Z", "updatedon": "2024-04-10T06:53:44.98Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//i-chroma-boditech-hscrp/181", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Boditech", "category": "immunoassay reagent", "tags": [ "#ImmunoassayTesting", "#MedicalInnovation", "#ImmunoassayInsights", "#LabTesting", "#HealthTech", "#HealthcareScience", "#MedicalDiagnosis", "#Immunodiagnostics", "#LabTech", "#Immunochemistry", "#LaboratoryTesting", "#DiagnosticInsights", "#HealthcareTech", "#DiagnosticTechnology", "#MedicalLabInnovation", "#DiagnosticTests", "#MedicalDetection", "#ImmunoassayAdvancements", "#MedicalLab", "#ImmunoassayLab", "#BiomarkerAnalysis", "#ImmunoassayTech", "#LabResults", "#ImmunoassayResultsMatter", "#ImmunoassayResults", "#HealthcareInnovation", "#LabQualityAssurance", "#DiagnosticInnovation", "#AntigenDetection", "#MedicalTechnology", "#LabMedicine", "#ImmunoassayProfessionals", "#ImmunoassayTestingTech", "#HealthTechAdvancements", "#BiomarkerTesting", "#DiagnosticPrecision", "#ClinicalTesting", "#ClinicalLab", "#ClinicalDiagnosis", "#AntibodyTesting", "#ImmunoassayResearch", "#Immunodetection", "" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "660e7dbb248447191c6bca06", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Avecon MaxLISA ", "description": "The ADA (Adenosine Deaminase) Kinetic clinical test is a diagnostic test used to measure the activity level of the enzyme adenosine deaminase in the body. Adenosine deaminase is an enzyme involved in the breakdown of purine nucleotides and is essential for the normal functioning of the immune system.\n\nADA Kinetic Pathology Lab Kit Manufacturers in India, which is an enzymatic diagnostic test used to measure the activity of the enzyme adenosine deaminase (ADA) in body fluids. We ensure the highest quality standards and provide reliable and accurate diagnostic kits for laboratory use.", "price": 950.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "India", "Avecon", "MaxLISA", "The ADA", "reliable", "breakdown", "body fluids", "immune system", "activity level", "laboratory use", "normal functioning", "purine nucleotides", "Kinetic clinical test", "accurate diagnostic kits", "enzymatic diagnostic test", "highest quality standards", "enzyme adenosine deaminase", "ADA Kinetic Pathology Lab Kit Manufacturers" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 174, "imageuri": "https://productimages.withfloats.com/actual/660e7dbe68341fdada45fee7.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/660e7dbe68341fdada45fee7.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-04-04T10:15:23.709Z", "updatedon": "2024-04-04T10:15:23.709Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//avecon-maxlisa-/174", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Avecon", "category": "Rapid Test", "tags": [ "#RapidTestKit", "#TestKitResults", "#HealthCheckup", "#DiagnosticTesting", "#QuickTesting", "#TestKitResultsMatter", "#HealthScreening", "#HealthCheck", "#QuickHealthScreening", "#MedicalTesting", "#MedicalDiagnosis", "#MedicalDiagnosisTools", "#QuickDiagnosis", "#DiagnosticSolutions", "#PointOfCareSolutions", "#PointOfCareTesting", "#HealthWellness", "#InnovativeTesting", "#HealthcareTech", "#RapidDetection", "#HealthAwareness", "#MedicalDevices", "#LabTech", "#RapidScreening", "#RapidResults", "#HealthcareInnovation", "#MedicalDevicesTech", "#DiagnosticInnovation", "#TestAccuracy", "#DiagnosticAccuracy", "#TestKitTechnology", "#MedicalScreening", "#HealthWellnessKit", "#HealthTech", "#RapidResponse", "#RapidHealthCheck", "#LabTesting", "#HomeTesting", "#AtHomeDiagnostics", "" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "660e796c40ea361bacf2e86d", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "MaxLINE HBsAg ", "description": "HBsAG Rapid Test\nThis is actually a direct fastening test that is done to screen the presence of Hepatitis B antibodies in serum or plasma or the entire blood. It is actually utilized to diagnose hepatitis infection. This is actually a responsive test that just takes about 10 minutes. The result can be seen directly without the use of any kind of instrument.\nTest procedure:\nMake sure that before doing this test, the HBsAG Rapid Test kit should be brought to the exact temperature as otherwise the results can be hampered. Before testing, it is a must-to-do step.\nFirst you need to open the pouch that is wrapped in a foil and then you have to eradicate the cartridge. This cassette needs to be placed on a flat and clean surface. \nThen the medical practitioner needs to hold the pipe in a vertical manner. In this pipe, you need to add the 3 drops of the sample. The results will be obtained within 15 minutes after the test is performed\nThe results shown after 20 minutes will not be considered correct. \nThere are numerous antiviral medications that need to be given to the patient diagnosed with this virus infection.", "price": 650.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "use", "kind", "pipe", "flat", "step", "foil", "pouch", "serum", "plasma", "result", "sample", "testing", "3 drops", "patient", "cassette", "presence", "cartridge", "instrument", "15 minutes", "10 minutes", "20 minutes", "entire blood", "clean surface", "MaxLINE HBsAg", "Test procedure", "virus infection", "vertical manner", "responsive test", "exact temperature", "hepatitis infection", "medical practitioner", "HBsAG Rapid Test kit", "direct fastening test", "Hepatitis B antibodies", "numerous antiviral medications" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 169, "imageuri": "https://productimages.withfloats.com/actual/660e79704715b5f00344f7c0.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/660e79704715b5f00344f7c0.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-04-04T09:57:00.787Z", "updatedon": "2024-04-04T09:57:00.787Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//maxline-hbsag-/169", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Avecon", "category": "Rapid Test", "tags": [ "#RapidTestKit", "#TestKitResults", "#HealthCheckup", "#DiagnosticTesting", "#QuickTesting", "#TestKitResultsMatter", "#HealthScreening", "#HealthCheck", "#QuickHealthScreening", "#MedicalTesting", "#MedicalDiagnosis", "#MedicalDiagnosisTools", "#QuickDiagnosis", "#DiagnosticSolutions", "#PointOfCareSolutions", "#PointOfCareTesting", "#HealthWellness", "#InnovativeTesting", "#HealthcareTech", "#RapidDetection", "#HealthAwareness", "#MedicalDevices", "#LabTech", "#RapidScreening", "#RapidResults", "#HealthcareInnovation", "#MedicalDevicesTech", "#DiagnosticInnovation", "#TestAccuracy", "#DiagnosticAccuracy", "#TestKitTechnology", "#MedicalScreening", "#HealthWellnessKit", "#HealthTech", "#RapidResponse", "#RapidHealthCheck", "#LabTesting", "#HomeTesting", "#AtHomeDiagnostics", "" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "660e7048b7244c1b144a96bd", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "MaxLINE Malaria Antigen PF/PAN", "description": "The Malaria Antigen Pf/Pan refers to a diagnostic test used in the detection of malaria infections. Malaria is a life-threatening disease caused by the Plasmodium parasite, which is transmitted through the bite of infected mosquitoes. We are Malaria Antigen Pf/Pan Manufacturer who deals with the high quality diagnostic kits which are supplied all over the India, in medical institutes, hospitals, pathology labs, and other institutions.", "price": 1200.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "bite", "India", "detection", "hospitals", "pathology labs", "diagnostic test", "malaria infections", "medical institutes", "other institutions", "Plasmodium parasite", "infected mosquitoes", "life-threatening disease", "The Malaria Antigen Pf/Pan", "high quality diagnostic kits", "MaxLINE Malaria Antigen PF/PAN", "Malaria Antigen Pf/Pan Manufacturer" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 161, "imageuri": "https://productimages.withfloats.com/actual/660e704cd447525ba6d4afd4.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/660e704cd447525ba6d4afd4.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-04-04T09:18:00.423Z", "updatedon": "2024-04-04T09:18:00.423Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//maxline-malaria-antigen-pf-pan/161", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Avecon", "category": "Rapid Test", "tags": [ "#RapidTestKit", "#TestKitResults", "#HealthCheckup", "#DiagnosticTesting", "#QuickTesting", "#TestKitResultsMatter", "#HealthScreening", "#HealthCheck", "#QuickHealthScreening", "#MedicalTesting", "#MedicalDiagnosis", "#MedicalDiagnosisTools", "#QuickDiagnosis", "#DiagnosticSolutions", "#PointOfCareSolutions", "#PointOfCareTesting", "#HealthWellness", "#InnovativeTesting", "#HealthcareTech", "#RapidDetection", "#HealthAwareness", "#MedicalDevices", "#LabTech", "#RapidScreening", "#RapidResults", "#HealthcareInnovation", "#MedicalDevicesTech", "#DiagnosticInnovation", "#TestAccuracy", "#DiagnosticAccuracy", "#TestKitTechnology", "#MedicalScreening", "#HealthWellnessKit", "#HealthTech", "#RapidResponse", "#RapidHealthCheck", "#LabTesting", "#HomeTesting", "#AtHomeDiagnostics", "" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
laboratory automation medical diagnostics?

Still searching for
laboratory automation medical diagnostics?

Chat with us