Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "659bbfb69bb0be169c7f794d",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Accu-Chek® Active blood glucose meter ",
"description": "Accu-Chek® Active blood glucose meter\nPersonalised Diabetes Coaching Accurate, no coding, easy\nItem Description\nThe Accu-Chek Active blood glucose meter packs many powerful features into a smaller size. No coding reduces handling steps, see test result averages up to 90 days, get alerts if your test strips are expired or if you’ve underdosed, re-dose within 10 seconds, set pre-and post-meal reminders to test, and more.\nBenefits and Features\naccurate:\n\nAccurate1 blood glucose measurement\neasy: \n\nNo coding for even easier blood glucose monitoring\neasy-to-read display (new typeface)\nintuitive handling with just 2 buttons\n safe:\n\nUnderdose detection\nvisual double check\n10 seconds re-dose option\n clever:\n\nPre- and postmeal markers\npostprandial reminder\n7,14,30 or now 90 day test averages\nUSB interface for data transfer\n Remark:\n\nPrevious Accu-Chek Active meter generations will be upgraded to no coding via black activation chip . Know more>>\n\n1The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014).\n\nAdditional specifications Meter type : \nAccu-Chek Active meter (Model GB)\n\n Catalogue no. / Serial no. : \nSee type plate on the back of the meter\n\n Test principle : \nDetermination of glucose in fresh capillary blood by reflectance photometry.\n\nBlood glucose values can be tested in whole blood or plasma.\n\nThe meter displays blood glucose values corresponding to those in plasma.\n\n Measuring interval : \n10-600 mg/dL\n\n Blood volume : \n1-2 μl\n\n Measuring time : \nTest strip in the meter: approx. 5 seconds\n\nTest strip outside the meter: approx. 08 seconds\n\n Power supply : \n1 battery (type CR2032)\n\n Battery life : \napprox. 1000 tests or approx. 1 year\n\n Automatic power-off : \nafter 30 or 90 seconds depending on operating status\n\n Memory : \n500 test results with time and date, as well as 7, 14, 30 and 90 days averages\n\n Temperature : \nDuring testing: +8 to +42°C\n\nDuring storage without battery: -25 to +70°C\n\nDuring storage with battery: -20 to +50°C\n\n Atmospheric humidity : \nDuring testing: up to 85% relative humidity\n\nDuring testing: up to 93% relative humidity\n\n Altitude: \nSea level to 4000 m\n\n Dimensions : \n97.8 x 46.8 x 19.1 mm\n\n Weight : \nWithout battery: approx. 46 g\n\nWith battery: approx. 50 g\n\n Display : \n96-segment liquid crystal display (LCD)\n\n Interface : \nUSB (Micro B)\n\n Safety class : \nIII\n\n Electromagnetic compatibility : \nThe Accu-Chek Active meter meets the electromagnetic immunity requirements and the electromagnetic emissions requirements as per EN 61326-2-6 and EN ISO 15197 Annex A.\n\nThe chosen basis for electrostatic discharge immunity testing was basic standard IEC 61000-4-2.\n\n Performance analysis : \nCalibration and traceability: The performance data for the Accu-Chek Active bGM system was calibrated using venous blood containing various glucose concentrations. Reference values are obtained using the hexokinase method, which is calibrated using the ID-GCMS method.\n\n Accuracy performance : \nThe Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014).\n\nHow to use Accu-Chek Active blood glucose meter\nTesting your blood glucose is an essential part of managing diabetes. The Accu-Chek Active blood glucose meter can help to make it convenient by giving you fast, hassle-free, and accurate results in 4 simple steps.\n\nInsert the glucose test strip\nPrick your finger with the lancet to draw out a blood drop.\nCarefully touch the blood drop onto the green field of the test strip.\nRead the blood glucose result.",
"price": 980.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"°C",
"30",
"50°",
"IEC",
"LCD",
"free",
"fast",
"date",
"back",
"file",
"basis",
"up to",
"finger",
"lancet",
"Weight",
"Memory",
"1 year",
"600 mg",
"plasma",
"Remark",
"alerts",
"coding",
"1-2 μl",
"19.1 mm",
"storage",
"Micro B",
"Model GB",
"Altitude",
"Benefits",
"2 buttons",
"Sea level",
"5 seconds",
"Serial no",
"Catalogue",
"1 battery",
"blood drop",
"type plate",
"1000 tests",
"90 seconds",
"test strips",
"type CR2032",
"test result",
"green field",
"Calibration",
"Temperature",
"Safety class",
"Battery life",
"smaller size",
"50 g Display",
"traceability",
"venous blood",
"Blood volume",
"new typeface",
"data transfer",
"Determination",
"USB interface",
"4 simple steps",
"ID-GCMS method",
"Measuring time",
"basic standard",
"essential part",
"handling steps",
"meal reminders",
"postmeal markers",
"Reference values",
"operating status",
"90 days averages",
"Item Description",
"performance data",
"accurate results",
"4000 m Dimensions",
"hexokinase method",
"glucose test strip",
"Measuring interval",
"intuitive handling",
"Automatic power-off",
"Atmospheric humidity",
"Blood glucose values",
"Accuracy performance",
"90 day test averages",
"blood glucose result",
"Performance analysis",
"meter Test principle",
"black activation chip",
"fresh capillary blood",
"EN ISO 15197 Annex A.",
"85% relative humidity",
"93% relative humidity",
"postprandial reminder",
"many powerful features",
"reflectance photometry",
"08 seconds Power supply",
"10 seconds re-dose option",
"The Accu-Chek Active meter",
"Electromagnetic compatibility",
"various glucose concentrations",
"Personalised Diabetes Coaching",
"easier blood glucose monitoring",
"The Accu-Chek Active bGM system",
"96-segment liquid crystal display",
"DIN EN ISO 15197:2013 requirements",
"Accurate1 blood glucose measurement",
"Additional specifications Meter type",
"electromagnetic immunity requirements",
"Accu-Chek® Active blood glucose meter",
"electromagnetic emissions requirements",
"Underdose detection visual double check",
"electrostatic discharge immunity testing",
"The Accu-Chek Active blood glucose meter",
"Previous Accu-Chek Active meter generations"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 132,
"imageuri": "https://productimages.withfloats.com/actual/659bbfb7945fbef921fe6c48.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/659bbfb7945fbef921fe6c48.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-01-08T09:26:14.799Z",
"updatedon": "2024-01-08T09:26:14.799Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN/products/accu-chek-active-blood-glucose-meter-/132",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Roche",
"category": "Glucometer",
"tags": [
"#Glucometer",
"#BloodGlucoseMonitoring",
"#DiabetesCare",
"#BloodSugarMeter",
"#DiabetesManagement",
"#HealthTech",
"#MedicalDevices",
"#DiabetesAwareness",
"#HealthAndWellness",
"#DigitalHealth",
"#DiabeticCare",
"#SelfMonitoring",
"#BloodSugarTest",
"#GlucoseMeter",
"#HealthTracking"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "658e94df665e3e1e4c420de5",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Maglumi prl KIt",
"description": "anti-PRL monoclonal antibody to label ABEI, and use another monoclonal antibody to Nano Magnetic Microbeads. Sample, Calibrator or Control with ABEI Label, and magnetic microbeads are mixed thoroughly and incubated at 37℃, forming a sandwich; after sediment in a magnetic field, decant the supernatant, then cycle washing for 1 time. Subsequently, the starter reagents are added and a flash chemiluminescent reaction is initiated. The light signal is measured by a photomultiplier as RLU within 3 seconds and is proportional to the concentration of PRL present in samples.",
"price": 5900.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"37℃",
"RLU",
"1 time",
"Sample",
"washing",
"Control",
"sandwich",
"sediment",
"3 seconds",
"ABEI Label",
"Calibrator",
"supernatant",
"light signal",
"concentration",
"magnetic field",
"photomultiplier",
"Maglumi prl KIt",
"starter reagents",
"Nano Magnetic Microbeads",
"anti-PRL monoclonal antibody",
"flash chemiluminescent reaction"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 49,
"imageuri": "https://productimages.withfloats.com/actual/658e94e0a25125856d56b0b2.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/658e94e0a25125856d56b0b2.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2023-12-29T09:43:59.201Z",
"updatedon": "2023-12-29T09:43:59.201Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//maglumi-prl-kit/49",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Maglumi",
"category": "immunoassay reagent",
"tags": [
"#ImmunoassayAnalyzer",
"#ClinicalChemistry",
"#LabAutomation",
"#DiagnosticTechnology",
"#MedicalDevices",
"#LaboratoryInstruments",
"#BioanalyticalTechnology",
"#DiagnosticInstruments",
"#AssayAnalysis",
"#ImmunoassayTech"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "658e900d665e3e1e4c420dae",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Maglumi T3 kit",
"description": " anti-T3 monoclonal antibody to label ABEI, and use a purified T3 antigen to label Nano Magnetic Microbeads. Sample, Calibrator, or Control ,ABEI Label, and Buffer are mixed thoroughly and incubated at 37℃, Then add Nano Magnetic Microbeads and incubated, the Sample and Nano Magnetic Microbeads competitively binding the ABEI Label, forming a immuno-complex ,after sediment in a magnetic field, decant the supernatant, then cycle washing for 1 time. Subsequently, the starter reagents are added and a flash chemiluminescent reaction is initiated. The light signal is measured by a photomultiplier as RLU within 3 seconds and is proportional to the concentration of T3 present in samples. ",
"price": 1800.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"37℃",
"RLU",
"1 time",
"Buffer",
"Sample",
"Control",
"sediment",
"3 seconds",
"Calibrator",
"ABEI Label",
"supernatant",
"light signal",
"concentration",
"magnetic field",
"immuno-complex",
"Maglumi T3 kit",
"photomultiplier",
"starter reagents",
"purified T3 antigen",
"Nano Magnetic Microbeads",
"anti-T3 monoclonal antibody",
"flash chemiluminescent reaction"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 47,
"imageuri": "https://productimages.withfloats.com/actual/658e900e166b9d9fd2d7d0b9.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/658e900e166b9d9fd2d7d0b9.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2023-12-29T09:23:25.075Z",
"updatedon": "2023-12-29T09:23:25.075Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//maglumi-t3-kit/47",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Maglum",
"category": "immunoassay reagent",
"tags": [
"#ImmunoassayAnalyzer",
"#ClinicalChemistry",
"#LabAutomation",
"#DiagnosticTechnology",
"#MedicalDevices",
"#LaboratoryInstruments",
"#BioanalyticalTechnology",
"#DiagnosticInstruments",
"#AssayAnalysis",
"#ImmunoassayTech"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "658e8e5a665e3e1e4c420d84",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "maglumi Beta HCG kit",
"description": "INTENDED USE The kit has been designed for the quantitative determination of free β-chains of human chorionic gonadotropin (free β-HCG) in human serum. The method can be used for samples over the range of 1.1-200 ng/ml. The test has to be performed on the Fully-auto chemiluminescence immunoassay (CLIA) analyzer MAGLUMI (Including Maglumi 600,Maglumi 1000,Maglumi 1000 Plus, Maglumi 2000,Maglumi 2000 Plus, Maglumi 3000 and Maglumi 4000). \nSUMMARY AND EXPLANATION OF THE TEST Human chorionic gonadotropin (HCG) is a dimeic glycoprotein with a molecular weight of 37,000 Dalton consisting of an α and a β-subunit. The α–subunit of HCG is nearly identical with the analogous subunit of the pituitary hormones LH, FSH, and TSH. HCG is produced by the syncytiotrophoblast of the placenta and can be detected in maternal serum immediately upon nidation. HCG is responsible for maintain the function of the ovarian corpus luteum. In normal pregnancy, HCG concentrations rapidly increase with a doubling rate of approximately two days. Pathologically decreased values indicate abnormal pregnancy (e.g. ectopic pregnancy). A sudden fall of HCG levels before the 8th -10th week of gestation should be considered as a serious indicator of imminent abortion. If pregnancy can be excluded, HCG levels above normal are highly likely to indicate the presence of malignant neoplasms, particularly germ-cell tumors (e.g. testicular tumors, chorionic or ovarian carcinoma. For use as a tumor marker, the test system has to recognize both HCG and β-HCG, since testicular and chorionic carcinomas mainly secrete the free β-chains rather than the intact HCG molecule\nPRINCIPLE OF THE TEST Sandwich immunoluminometric assay: Use an anti-free-β-HCG monoclonal antibody to label ABEI, and use another monoclonal antibody to label FITC. Sample, Calibrators, or Control with ABEI Label, FITC Label and magnetic microbeads coated with anti-FITC are mixed thoroughly and incubated at 37℃, forming a sandwich; After sediment in a magnetic field, decant the supernatant, cycle washing for 1 time. Subsequently, the starter reagents are added and a flash chemiluminescent reaction is initiated. The light signal is measured by a photomultiplier as RLU within 3 seconds and is proportional to the concentration of free-β-HCG present in samples. ",
"price": 4900.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"LH",
"37℃",
"RLU",
"THE",
"FSH",
"TSH",
"range",
"1 time",
"method",
"values",
"samples",
"Control",
"1.1-200",
"SUMMARY",
"two days",
"nidation",
"placenta",
"presence",
"function",
"sediment",
"3 seconds",
"gestation",
"PRINCIPLE",
"β-subunit",
"α–subunit",
"anti-FITC",
"ABEI Label",
"FITC Label",
"HCG levels",
"supernatant",
"EXPLANATION",
"sudden fall",
"test system",
"Calibrators",
"human serum",
"INTENDED USE",
"light signal",
"tumor marker",
"doubling rate",
"37,000 Dalton",
"free β-chains",
"8th -10th week",
"CLIA) analyzer",
"maternal serum",
"magnetic field",
"photomultiplier",
"molecular weight",
"normal pregnancy",
"starter reagents",
"germ-cell tumors",
"imminent abortion",
"serious indicator",
"Including Maglumi",
"ectopic pregnancy",
"testicular tumors",
"analogous subunit",
"ovarian carcinoma",
"HCG concentrations",
"pituitary hormones",
"intact HCG molecule",
"syncytiotrophoblast",
"dimeic glycoprotein",
"malignant neoplasms",
"magnetic microbeads",
"maglumi Beta HCG kit",
"chorionic carcinomas",
"ovarian corpus luteum",
"quantitative determination",
"flash chemiluminescent reaction",
"TEST Human chorionic gonadotropin",
"anti-free-β-HCG monoclonal antibody",
"TEST Sandwich immunoluminometric assay",
"Fully-auto chemiluminescence immunoassay"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 46,
"imageuri": "https://productimages.withfloats.com/actual/658e8e5bf874a788b5164c31.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/658e8e5bf874a788b5164c31.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2023-12-29T09:16:10.493Z",
"updatedon": "2023-12-29T09:16:10.493Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN/products/maglumi-beta-hcg-kit/46",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Maglumi",
"category": "immunoassay reagent",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6b3794dd80b30515fcf02d",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "ELECTROLYTE SPOTCHEM EL 1520 ARKRAY",
"description": "ELECTROLYTE SPOTCHEM EL 1520 ARKRAY:-\n\n SPOTCHEM EL is an electrolyte analysis system with capacity for total electrolyte analysis requirements in all fields.\nFast, accurate and simple electrolyte analysis of body fluids-essential in an emergency.\n• Whole blood, serum, plasma and urine can be measured with 22 ul\n• Two types of special twin-pipettes are available.\n• Easy calibration can be completed with magnetic card\n• Na, K, Cl are measured at the same time on the same E-Plate\n \n",
"price": 150000.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"time",
"body",
"types",
"urine",
"Whole",
"plasma",
"special",
"accurate",
"capacity",
"magnetic",
"SPOTCHEM EL",
"Easy calibration",
"electrolyte analysis system",
"simple electrolyte analysis",
"total electrolyte analysis requirements"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 19,
"imageuri": "https://productimages.withfloats.com/actual/5a1540921e3abc0a2c2974af.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5a1540921e3abc0a2c2974af.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2017-11-22T07:40:10.035Z",
"updatedon": "2018-12-14T00:29:27.117Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN/products/electrolyte-spotchem-el-1520-arkray/19",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": null,
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "6592635399fce81cb82de589",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Snibe Fully Automatic Maglumi 800 Chemiluminesescence Immunoassay System( CLIA)",
"description": "Product DescriptionWe are successfully meeting the varied requirements of our clients by providing the best quality range of Maglumi 800 Fully Automatic Immunoassay Analyzer.\n\nPrinciple Of Luminescence:\nNon-Enzyme Involved Flash Chemiluminescence, Long Stability Of Reagents\n\nSample Loading\nUp To 40 Sample Tubes\nContinuous Loading, Stat Available\nAnalyzer Auto Numbered\nLis Connection\nRefrigerated Sample Area With Independent Power Supply\n\nReagent Loading\n9 Reagents On Board\nContinuous Loading\nRfid Reading All Info Of Reagents\nRefrigerated Reagent Area\n\nReagent Features:\nIntegrated Kit, Ready-To-Use, No Pretreatment Required\nIntegrated Kit Including Calibrators\nUsing Superparamagnetic Microbeads\nRfid Tag Storing All Info Of Reagent\nRfid Tag With Built-In Master Curve\n2-Point Calibration To Adjust Master Curve\n\nOther Features\nClot Detection\nLiquid Level Detection For Reagent\nOptional Ratio For Sample Dilution\nAuto Dilution For High Concentration Sample\nConstant 37 Incubation",
"price": 550000.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"Info",
"CLIA",
"Board",
"clients",
"Numbered",
"Reagents",
"Principle",
"Calibrators",
"Pretreatment",
"Master Curve",
"Auto Dilution",
"Other Features",
"Clot Detection",
"Optional Ratio",
"Long Stability",
"Lis Connection",
"Sample Loading",
"40 Sample Tubes",
"Sample Dilution",
"Reagent Loading",
"Reagent Rfid Tag",
"Reagent Features",
"best quality range",
"Continuous Loading",
"varied requirements",
"2-Point Calibration",
"Product DescriptionWe",
"Liquid Level Detection",
"Integrated Kit Including",
"Refrigerated Sample Area",
"Independent Power Supply",
"Refrigerated Reagent Area",
"Superparamagnetic Microbeads",
"Non-Enzyme Involved Flash Chemiluminescence",
"High Concentration Sample Constant 37 Incubation",
"Maglumi 800 Fully Automatic Immunoassay Analyzer",
"Snibe Fully Automatic Maglumi 800 Chemiluminesescence Immunoassay System"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 72,
"imageuri": "https://productimages.withfloats.com/actual/65926356955199af3b5d1c09.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/65926356955199af3b5d1c09.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-01-01T07:01:39.602Z",
"updatedon": "2024-01-01T07:01:39.602Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//snibe-fully-automatic-maglumi-800-chemiluminesescence-immunoassay-system-clia-/72",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Snibe Maglumi ",
"category": "immunoassay Analyzer",
"tags": [
"#ImmunoassayAnalyzer",
"#ClinicalChemistry",
"#LabAutomation",
"#DiagnosticTechnology",
"#MedicalDevices",
"#LaboratoryInstruments",
"#BioanalyticalTechnology",
"#DiagnosticInstruments",
"#AssayAnalysis",
"#ImmunoassayTech"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "658e932545a4a11780c1aa80",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Maglumi Rubella IgG kit",
"description": "anti-human IgG is used to label ABEI, and use purified Rubella antigen to coat nano magnetic microbeads. Sample, Calibrator or Control with Buffer(goat Anti-human IgM, goat Anti-human IgA) and nano magnetic microbeads coated with Rubella antigen are mixed thoroughly and incubated at 37℃ and cycle washing for 1 time. Then add ABEI Label, incubation and form a sandwich, then washing for the 2nd time. Subsequently, the starter reagents are added and a flash chemiluminescent reaction is initiated. The light signal is measured by a photomultiplier as RLU within 3 seconds and is proportional to the concentration of Rubella IgG present in samples",
"price": 5500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"37℃",
"RLU",
"Buffer",
"Sample",
"1 time",
"Control",
"sandwich",
"2nd time",
"3 seconds",
"Calibrator",
"ABEI Label",
"incubation",
"light signal",
"concentration",
"anti-human IgG",
"photomultiplier",
"Rubella antigen",
"starter reagents",
"goat Anti-human IgM",
"goat Anti-human IgA",
"Maglumi Rubella IgG kit",
"nano magnetic microbeads",
"flash chemiluminescent reaction"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 48,
"imageuri": "https://productimages.withfloats.com/actual/658e9327412d032667b87457.png",
"tileimageuri": "https://productimages.withfloats.com/tile/658e9327412d032667b87457.png",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2023-12-29T09:36:37.164Z",
"updatedon": "2023-12-29T09:36:37.164Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN/products/maglumi-rubella-igg-kit/48",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Maglumi",
"category": "immunoassay reagent",
"tags": [
"#ImmunoassayAnalyzer",
"#ClinicalChemistry",
"#LabAutomation",
"#DiagnosticTechnology",
"#MedicalDevices",
"#LaboratoryInstruments",
"#BioanalyticalTechnology",
"#DiagnosticInstruments",
"#AssayAnalysis",
"#ImmunoassayTech"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6b3794dd80b30515fcf07b",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Microscope Standard TUBLER",
"description": "Microscope Standard:-\n\nDescription:-\n\nStandard Microscope is widely used in different laboratory research works. These are appreciated for features like a compact design, great performance and user friendly functions. Our ranges of standard microscope are made from supreme grade material with advanced features. They are sturdily constructed and are made as per international industry standards and are very easy to operate and maintain.\n\n\nMain features of the Microscope are :\n\n Tube with mechanical tube length 160mm with triple revolving nose piece\n Separate coarse & fine adjustment\n Square stage with clips for holding the slides\n Double lens bright field ABBE condenser NA 1.25 is fixed with the stage with iris diaphragm and swing out filter holder\n Illumination by plano concave mirror.",
"price": 9900.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"operate",
"compact",
"features",
"Square stage",
"Illumination",
"user friendly",
"iris diaphragm",
"Separate coarse",
"mechanical tube",
"great performance",
"standard microscope",
"supreme grade material",
"different laboratory research",
"international industry standards",
"Double lens bright field ABBE condenser NA"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 22,
"imageuri": "https://productimages.withfloats.com/actual/5a154c3aa677470a7cc321ed.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5a154c3aa677470a7cc321ed.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2017-11-22T10:06:49.599Z",
"updatedon": "2018-12-14T00:32:48.484Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//microscope-standard-tubler/22",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": null,
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6b3794dd80b30515fcf056",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Finecare-Analyzer",
"description": "Finecare-Analyzer:-\n\nDescription:-\n\nFinecare Analyzer is a portable instrument for fluorescence detection to quantify concentration of various kind of analytes in blood. It can be used both in a central laboratory and a point-of-care testing facility. Finecare Analyzer uses a laser as the excitation light source.The emitted light from the fluorescence dye is collected and converted into an electrical signal. The signal is closely related to the amount of fluorescing dye molecules present on the spot under examination. Finecare FIA Meter is full quantitative detection, with small size, simple operation and multiple test items in one machine\n\nTest items:\n\n• Inflammatory items: hs CRP & CRP, PCT\n• Caridac markers: NT-proBNP Troponin-I Myoglobin, CK-MB, H-FABP\n• Coagulation markers: D-Dimer\n• Other markers: MAU, AFP, PSA, HbA1C, etc.\n• Fig 1:Finecare FIA Meter Features-Front View\n• Fig 2:Finecare FIA Meter Features-Left View\n• Fig 3:Power Adapter for the Equipment Fig 4:Touch Pen\n• Fig 5:Test Device Features (Remark: You shall buy the Test Devices separately)\n• Fig 6:Test Device ID Chip\n• Fig 7:Quality Test Card\n• System Precision: CV=15%\n\nPhysical Description:\n\nDimensions 250(L)×258(W)×104(H)mm\n\nWeight 2.5 kg\n\nPower supply 100-240 AC, 50-60 Hz\n\nData output On board screen/Printer/PC\n\nOperation Environmental Set-up:\n\nTemperature 10°C~30°C\n\n\nHumidity 10%~80%\n\nAtmospheric pressure 86kPa~106kPa\n\n\nOperating Altitude < 2000 m\n\n\nLocation Dry, clean,flat,horizontal surface away from direct sunlight, mechanical vibration,& strong electromagnetic interferences.\n\n\nStorage Environmental:\nTemperature-10°C~50°C\n\nHumidity 10%~80%\n\nStorage elevation 0~2000 m\n\n\nOptical Description:\n\n\nExcitation Light Source\n\n\nLED, 470 nm\n\n\n\nDetector\n\n\n525 nm Photodiode\n\n\nOther:\n\n\nInput\n\n\nFor power adapter\n\n\n100–240 V AC, 50/60 Hz, 2 A\n\n\n\nFor host\n\n\n12 V DC, 5 A\n\n\n\nDriver Motor\n\n\n12 V\n\n\n\nBuilt-in Printer\n\n\nThermal\n\n\n\nDisplay\n\n\nLCD\n\n\n\nKey pad\n\n\n4 function keys\n\n\n",
"price": 67000.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"Equipment Fig",
"Environmental",
"Device Features",
"fluorescence dye",
"excitation light",
"simple operation",
"Finecare Analyzer",
"full quantitative",
"Finecare FIA Meter",
"central laboratory",
"multiple test items",
"portable instrument",
"dye molecules present",
"fluorescence detection",
"strong electromagnetic"
],
"isarchived": false,
"isavailable": false,
"applicationid": null,
"productindex": 21,
"imageuri": "https://productimages.withfloats.com/actual/657aa81dbd689fcabf07489c.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/657aa81dbd689fcabf07489c.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2017-11-22T09:57:18.806Z",
"updatedon": "2023-12-14T07:00:23.455Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN/products/finecare-analyzer/21",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": true,
"maxcodorders": -1,
"maxprepaidonlineorders": -1,
"uniquepaymenturl": null,
"brandname": "",
"category": "",
"tags": [],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}