Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

RAJBIOSISPVTLTD 57f353489ec66821d8f93788 Products https://www.rajbiosis.in
{ "products": [ { "_id": "65927f82545ff1187c886bad", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "I Chroma II A compact and easy-to-use fluorescence based POCT immunoassay analyzer ", "description": "ichroma IIA compact and easy-to-use, fluorescence based POCT immunoassay analyzer, Point of care Analyzer\nichroma II is a compact, easy-to-use diagnostic immuno-analyzer to measure the presence of various biomarkers for cardiac, cancer, hormones, infectious diseases, autoimmune diseases, and metabolic diseases.\n\n\niChroma II is an advanced immunoassay reader in our SwifTest range of POC devices. It utilizes the latest immuno-fluorescence technology and provides a simple, fast and reliable method to diagnose a patient’s condition or monitor a treatment response.\n\nIChroma II provides results correlating with the laboratory along with all the benefits offered by point-of-care like quick test time, portability, low running costs & user friendly operation making it an ideal choice for any laboratory. IChroma II can be useful for diagnosing conditions such as infection, diabetes, hormonal conditions, cardiovascular diseases, renal injury and cancers etc. in blood, serum, plasma, urine or other samples, in quantitative or semi-quantitative ways.\n\n iChroma is a registered trademark of Boditech Med Inc.\n\n\nIChroma II Features\nFully Portable Battery and/or AC power), Lightweight Reader\nHigh Throughput Patient Testing: 30 tests/hr\nWidest Test Menu on a Single Platform: 44 Parameters across 8 Therapeutic Test Profiles\nLarge Memory: 1000 Samples, 1000 QC & 100 IDs\nConvenient: 7” Colour Touch Screen, User-Friendly Interface\nSmart Calibration Chip: No Reagent Wastage & Calibration Failure\nInternal & External Quality Controls available\nLIS/HIS Compatible\nEnhanced Data Management & Connectivity: USB port/Ethernet/SD card slot\n\n\n", "price": 67000.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "serum", "blood", "Point", "urine", "plasma", "cancer", "compact", "cardiac", "results", "1000 QC", "100 IDs", "hormones", "presence", "benefits", "Internal", "diabetes", "30 tests", "AC power", "infection", "laboratory", "portability", "I Chroma II", "ichroma IIA", "POC devices", "1000 Samples", "renal injury", "ideal choice", "simple, fast", "Connectivity", "44 Parameters", "other samples", "care Analyzer", "SwifTest range", "quick test time", "Reagent Wastage", "Single Platform", "reliable method", "Boditech Med Inc", "Widest Test Menu", "low running costs", "various biomarkers", "LIS/HIS Compatible", "metabolic diseases", "treatment response", "hormonal conditions", "Calibration Failure", "infectious diseases", "IChroma II Features", "autoimmune diseases", "registered trademark", "7” Colour Touch Screen", "Smart Calibration Chip", "Fully Portable Battery", "semi-quantitative ways", "cardiovascular diseases", "user friendly operation", "User-Friendly Interface", "Enhanced Data Management", "POCT immunoassay analyzer", "External Quality Controls", "diagnostic immuno-analyzer", "advanced immunoassay reader", "USB port/Ethernet/SD card slot", "latest immuno-fluorescence technology", "8 Therapeutic Test Profiles Large Memory", "Lightweight Reader High Throughput Patient Testing" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 82, "imageuri": "https://productimages.withfloats.com/actual/65927f84d5680f923376699e.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/65927f84d5680f923376699e.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-01-01T09:01:54.708Z", "updatedon": "2024-01-01T09:01:54.708Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN/products/i-chroma-ii-a-compact-and-easy-to-use-fluorescence-based-poct-immunoassay-analyzer-/82", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Boditech ichroma", "category": "Immunoassay analyzer", "tags": [ "#ImmunoassayAnalyzer", "#DiagnosticTechnology", "#LabInstrumentation", "#MedicalDiagnosis", "#HealthcareTech", "#BiomedicalScience", "#ClinicalLab", "#DiagnosticEquipment", "#MedicalDevices", "#Immunodiagnostics", "#LaboratoryTech", "#DiagnosticsTech", "#AssayAutomation", "#HighThroughput", "#BiomedicalTechnology", "#MedicalInnovation", "#HealthTech", "#DiagnosticSolutions", "#LabAutomation", "#ClinicalPathology" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "658e8e5a665e3e1e4c420d84", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "maglumi Beta HCG kit", "description": "INTENDED USE The kit has been designed for the quantitative determination of free β-chains of human chorionic gonadotropin (free β-HCG) in human serum. The method can be used for samples over the range of 1.1-200 ng/ml. The test has to be performed on the Fully-auto chemiluminescence immunoassay (CLIA) analyzer MAGLUMI (Including Maglumi 600,Maglumi 1000,Maglumi 1000 Plus, Maglumi 2000,Maglumi 2000 Plus, Maglumi 3000 and Maglumi 4000). \nSUMMARY AND EXPLANATION OF THE TEST Human chorionic gonadotropin (HCG) is a dimeic glycoprotein with a molecular weight of 37,000 Dalton consisting of an α and a β-subunit. The α–subunit of HCG is nearly identical with the analogous subunit of the pituitary hormones LH, FSH, and TSH. HCG is produced by the syncytiotrophoblast of the placenta and can be detected in maternal serum immediately upon nidation. HCG is responsible for maintain the function of the ovarian corpus luteum. In normal pregnancy, HCG concentrations rapidly increase with a doubling rate of approximately two days. Pathologically decreased values indicate abnormal pregnancy (e.g. ectopic pregnancy). A sudden fall of HCG levels before the 8th -10th week of gestation should be considered as a serious indicator of imminent abortion. If pregnancy can be excluded, HCG levels above normal are highly likely to indicate the presence of malignant neoplasms, particularly germ-cell tumors (e.g. testicular tumors, chorionic or ovarian carcinoma. For use as a tumor marker, the test system has to recognize both HCG and β-HCG, since testicular and chorionic carcinomas mainly secrete the free β-chains rather than the intact HCG molecule\nPRINCIPLE OF THE TEST Sandwich immunoluminometric assay: Use an anti-free-β-HCG monoclonal antibody to label ABEI, and use another monoclonal antibody to label FITC. Sample, Calibrators, or Control with ABEI Label, FITC Label and magnetic microbeads coated with anti-FITC are mixed thoroughly and incubated at 37℃, forming a sandwich; After sediment in a magnetic field, decant the supernatant, cycle washing for 1 time. Subsequently, the starter reagents are added and a flash chemiluminescent reaction is initiated. The light signal is measured by a photomultiplier as RLU within 3 seconds and is proportional to the concentration of free-β-HCG present in samples. ", "price": 4900.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "LH", "37℃", "RLU", "THE", "FSH", "TSH", "range", "1 time", "method", "values", "samples", "Control", "1.1-200", "SUMMARY", "two days", "nidation", "placenta", "presence", "function", "sediment", "3 seconds", "gestation", "PRINCIPLE", "β-subunit", "α–subunit", "anti-FITC", "ABEI Label", "FITC Label", "HCG levels", "supernatant", "EXPLANATION", "sudden fall", "test system", "Calibrators", "human serum", "INTENDED USE", "light signal", "tumor marker", "doubling rate", "37,000 Dalton", "free β-chains", "8th -10th week", "CLIA) analyzer", "maternal serum", "magnetic field", "photomultiplier", "molecular weight", "normal pregnancy", "starter reagents", "germ-cell tumors", "imminent abortion", "serious indicator", "Including Maglumi", "ectopic pregnancy", "testicular tumors", "analogous subunit", "ovarian carcinoma", "HCG concentrations", "pituitary hormones", "intact HCG molecule", "syncytiotrophoblast", "dimeic glycoprotein", "malignant neoplasms", "magnetic microbeads", "maglumi Beta HCG kit", "chorionic carcinomas", "ovarian corpus luteum", "quantitative determination", "flash chemiluminescent reaction", "TEST Human chorionic gonadotropin", "anti-free-β-HCG monoclonal antibody", "TEST Sandwich immunoluminometric assay", "Fully-auto chemiluminescence immunoassay" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 46, "imageuri": "https://productimages.withfloats.com/actual/658e8e5bf874a788b5164c31.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/658e8e5bf874a788b5164c31.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2023-12-29T09:16:10.493Z", "updatedon": "2023-12-29T09:16:10.493Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//maglumi-beta-hcg-kit/46", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Maglumi", "category": "immunoassay reagent", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "5b6b3793dd80b30515fcee41", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "BPL ECG Cardiart 6208 View", "description": "Features: \n\n\n \n\n\n\n\n\n\n\n\n+Simultaneous 3 channel ECG recording with 12 lead simultaneous acquisition and Arrhythmia Detection in auto mode\n+Large Colour LCD Display enabling the preview of ECG and preview of patient information entry\n+Internal memory which allows storage of up to 200 ECGs\n+The compact, light weight (only 2.5 kg) ensures device portability\n+Designed for safe use, both on power line as well as battery\n+High performance Li-ion rechargeable battery enables mains independent operations and provides battery use after charging\n+Removes interference from power line, muscle tremor, etc. with automatic base line correction\n+Enables the storage and transfer of ECG recordings from an ECG machine to PC\n+Facilitates transfer of ECGs from the device to USB in PDF format\n+Data transfer to PC through Ethernet port, pacemaker detection (Optional)", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "power line", "ECG machine", "channel ECG", "battery use", "ECG Cardiart", "ECG recordings", "ensures device", "Colour LCD Display", "automatic base line", "pacemaker detection", "patient information", "rechargeable battery", "Arrhythmia Detection", "mains independent operations", "lead simultaneous acquisition" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 10, "imageuri": "https://productimages.withfloats.com/actual/5a140519566bac04504608f0.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/5a140519566bac04504608f0.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2017-11-21T10:51:05.757Z", "updatedon": "2018-08-08T18:33:55.832Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//bpl-ecg-cardiart-6208-view/10", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": null, "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "66337a27c1886b1a14f0bc13", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "AGAPPE Mispa Chem Dx Auto Dry Biochemistry Analyzer", "description": "Overview\nA fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely\n\n\nLow Sample Consumption\nEasy to Use\nMaintenance Free\nAccurate Result\nDisposable reagent disc\nSample volume: 100µl \nTesting time: 12 minutes / sample \nTemperature: 37°C ± 0.3°C \nResolution: 0.001Abs Absorbance: 0-3.0Abs \nSample type: Heparinized whole blood, serum, plasma (heparin)\nQC&Calibration: IQC (Intelligent Quality Control/Calibration) \nWork condition: Temperature:10-30°C Humidity: 30%-70%\nTesting method: End point, kinetic, fixed time, turbidmetry etc \nLight source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours \nPower supply: AC 100V-240V, 50-60Hz \nDisplay: Android 7.0 inch 800*480, multi-point capacitive touch screen \nStorage: 500,000 results \nPrinter: Built-in thermal printer Interface: 4 USB ports, 1 LAN port \nDimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)", "price": 375000.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "0.", "37", "7kg", "12V", "IQC", "G.W.", "240V", "less", "N.W.", "100µ", "blood", "475mm", "serum", "plasma", "change", "engine", "QR code", "diluent", "AC 100V", "heparin", "kinetic", "life span", "End point", "algorithm", "12 minutes", "fixed time", "Resolution", "19 General", "absorbance", "4 USB ports", "Sample type", "turbidmetry", "Light source", "Testing time", "3 to 4 drops", "Sample volume", "disc function", "QC&Calibration", "Work condition", "Accurate Result", "Android 7.0 inch", "Maintenance Free", "reagent dry disc", "end concentration", "reaction stability", "sample Temperature", "calibration details", "absorption spectrum", "1 LAN port Dimension", "Halogen tungsten lamp", "Low Sample Consumption", "Disposable reagent disc", "2500 hours Power supply", "500,000 results Printer", "Special chemistry tests", "absorption spectroscopy", "optimal disc performance", "lyophilized reagent beads", "thermal printer Interface", "Intelligent Quality Control", "POC Auto Dry Biochemistry Analyzer", "intelligent internal quality control system", "multi-point capacitive touch screen Storage", "AGAPPE Mispa Chem Dx Auto Dry Biochemistry Analyzer Overview" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 336, "imageuri": "https://productimages.withfloats.com/actual/66337a2ae837fe0918be91c5.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/66337a2ae837fe0918be91c5.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-05-02T11:33:59.219Z", "updatedon": "2024-05-02T11:33:59.219Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//agappe-mispa-chem-dx-auto-dry-biochemistry-analyzer/336", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "AGAPPE", "category": "Biochemistry Analyzer", "tags": [ "#ChemicalTesting", "BiochemistryAnalyzer", "#LabTestingSolutions", "#LabMedicine", "#ClinicalChemistry", "#MedicalLabInnovation", "#BiochemicalAnalysis", "#LabTesting", "#ChemicalAnalysisTech", "#HealthcareInnovation", "#MedicalDiagnosis", "#LabQualityAssurance", "#LabTech", "#ChemistryLab", "#ClinicalTesting", "#MedicalLabTesting", "#HealthcareTech", "#HealthTechAdvancements", "#DiagnosticTechnology", "#LabAnalysis", "#BiochemicalMarkers", "#LabResultsMatter", "#DiagnosticTests", "#LabDataAnalysis", "#ClinicalDiagnosis", "#MedicalInnovation", "#DiagnosticsInsights", "#BiochemistryLab", "#LaboratoryScience", "#BiochemistryLabTech", "#HealthcareDiagnosis", "#HealthTech", "#PrecisionDiagnostic", "#LabScience", "#Biomarkers", "#MedicalDetection", "#MedicalTesting", "#MedicalLab", "#LabExcellence", "#LabAccuracy", "#ChemicalAnalysis", "#HealthcareScience", "" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "6613e3311f80b80ba8e06ff0", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Bd Ultra Fine Pen Needles / Easy Flow / penta Point", "description": "Product highlights\n\nCompatible with leading diabetes medication pens\nFeatures a no-pinch technique\nReduces the risk of IM injection\nEnables easy penetration into the skin", "price": 15.5, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "risk", "skin", "Easy Flow", "penta Point", "IM injection", "pinch technique", "easy penetration", "Product highlights", "Bd Ultra Fine Pen Needles", "leading diabetes medication pens" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 176, "imageuri": "https://productimages.withfloats.com/actual/6613e336de72b118ec8036ed.jpeg", "tileimageuri": "https://productimages.withfloats.com/tile/6613e336de72b118ec8036ed.jpeg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-04-08T12:29:37.785Z", "updatedon": "2024-04-08T12:29:37.785Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//bd-ultra-fine-pen-needles-easy-flow-penta-point/176", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "BD", "category": "Needles", "tags": [ "Bd Ultra Fine Pen Needles", "Easy Flow", "penta Point" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "660e7dbb248447191c6bca06", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Avecon MaxLISA ", "description": "The ADA (Adenosine Deaminase) Kinetic clinical test is a diagnostic test used to measure the activity level of the enzyme adenosine deaminase in the body. Adenosine deaminase is an enzyme involved in the breakdown of purine nucleotides and is essential for the normal functioning of the immune system.\n\nADA Kinetic Pathology Lab Kit Manufacturers in India, which is an enzymatic diagnostic test used to measure the activity of the enzyme adenosine deaminase (ADA) in body fluids. We ensure the highest quality standards and provide reliable and accurate diagnostic kits for laboratory use.", "price": 950.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "India", "Avecon", "MaxLISA", "The ADA", "reliable", "breakdown", "body fluids", "immune system", "activity level", "laboratory use", "normal functioning", "purine nucleotides", "Kinetic clinical test", "accurate diagnostic kits", "enzymatic diagnostic test", "highest quality standards", "enzyme adenosine deaminase", "ADA Kinetic Pathology Lab Kit Manufacturers" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 174, "imageuri": "https://productimages.withfloats.com/actual/660e7dbe68341fdada45fee7.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/660e7dbe68341fdada45fee7.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-04-04T10:15:23.709Z", "updatedon": "2024-04-04T10:15:23.709Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//avecon-maxlisa-/174", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Avecon", "category": "Rapid Test", "tags": [ "#RapidTestKit", "#TestKitResults", "#HealthCheckup", "#DiagnosticTesting", "#QuickTesting", "#TestKitResultsMatter", "#HealthScreening", "#HealthCheck", "#QuickHealthScreening", "#MedicalTesting", "#MedicalDiagnosis", "#MedicalDiagnosisTools", "#QuickDiagnosis", "#DiagnosticSolutions", "#PointOfCareSolutions", "#PointOfCareTesting", "#HealthWellness", "#InnovativeTesting", "#HealthcareTech", "#RapidDetection", "#HealthAwareness", "#MedicalDevices", "#LabTech", "#RapidScreening", "#RapidResults", "#HealthcareInnovation", "#MedicalDevicesTech", "#DiagnosticInnovation", "#TestAccuracy", "#DiagnosticAccuracy", "#TestKitTechnology", "#MedicalScreening", "#HealthWellnessKit", "#HealthTech", "#RapidResponse", "#RapidHealthCheck", "#LabTesting", "#HomeTesting", "#AtHomeDiagnostics", "" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "659bd2c1286dcf170c8bf823", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "TURBOSTAT – SEMI AUTOMATED CHEMISTRY ANALYZER", "description": "Photometric linearity arrange from 0 to 4.0 Abs\n8 filters standard wavelength and 2 more free position\nWindows-based user-friendly interface with high speed CPU processor\nAnalysis method: Endpoint, Kinetic, Fixed time, Turbidimetry, Multipoint, Factor etc.,\nReal-time reaction monitoring graph for each test\nInteractive test menu with 300 parameters\nResult storage up to 2,00,000\n7” touch screen TFT LCD display\n4 USB Host, 1 USB slave and 1 Ethernet port for efficient support\nBuilt-in thermal printer\n\nLinear Measuring Range\t0 to 4.0Abs\nLight Source\tTungsten Lamp with lamp saver feature\nStandard Wavelength:\t340, 405, 450, 505, 546, 578, 630 nm and 2 more for optional\nModes:\tEnd-point, Two-point, Kinetic, Multi-point, Factor\nTest Menu:\t300 open programmable test option\nIlluminated volume of Flow Cell:\t32 μL\nPrinter:\tThermal Printer\nDisplay:\t7 inches LCD touch screen\nStorage:\t2,00,000 Result\nInterface:\t4 USB Hosts, 1USB Slave, 1 Ethernet port.\nPower Requirement:\t100~240VAC; 50/60Hz\nDimensions:\t400mm (L) x 300mm (W) x 160mm (H)", "price": 949500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "578", "300mm", "400mm", "160mm", "240VAC", "630 nm", "4.0 Abs", "Kinetic", "Endpoint", "TURBOSTAT", "End-point", "Flow Cell", "Two-point", "4 USB Host", "1USB Slave", "Multipoint", "Fixed time", "1 USB slave", "Turbidimetry", "free position", "32 μL Printer", "Result storage", "optional Modes", "300 parameters", "7” touch screen", "1 Ethernet port", "TFT LCD display", "Factor Test Menu", "efficient support", "Power Requirement", "Illuminated volume", "lamp saver feature", "Photometric linearity", "Interactive test menu", "Thermal Printer Display", "2,00,000 Result Interface", "8 filters standard wavelength", "Abs Light Source Tungsten Lamp", "300 open programmable test option", "SEMI AUTOMATED CHEMISTRY ANALYZER", "7 inches LCD touch screen Storage", "Real-time reaction monitoring graph", "Windows-based user-friendly interface", "thermal printer Linear Measuring Range", "high speed CPU processor Analysis method" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 138, "imageuri": "https://productimages.withfloats.com/actual/659bd2c3472a69e02065108d.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/659bd2c3472a69e02065108d.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-01-08T10:47:29.461Z", "updatedon": "2024-01-08T10:47:29.461Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//turbostat-semi-automated-chemistry-analyzer/138", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "CPC", "category": "Clinical Chemistry", "tags": [ "#BiochemistryAnalyzer", "#ClinicalChemistry", "#LabEquipment", "#MedicalTechnology", "#DiagnosticTests", "#HealthcareTech", "#LaboratoryScience", "#MedicalDevices", "#BiomedicalScience", "#HealthTech", "#DiagnosticInstruments", "#AnalyticalChemistry", "#BiochemicalAnalysis", "#ClinicalDiagnostics", "#HealthcareInnovation" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "659bd01a264c830308a51c15", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "ICHEM PRIME – SYSTEM PACK REAGENTS FOR TURBOCHEM PRIME", "description": "Guaranteed number of tests ensuring zero wastage.\nEnsures on-board and calibaration stability.\nEasy inventory.\nKITS\nAlbumin\nAmylase\nBilirubin Direct\nBillirubin total\nCalcium\nCholesterol\nCK MB\nCK NAC\nCreatinine\nGGT\nGlucose\nLDH L\nMagnesium\nPhosphorus\nProtein\nTriglycerides\nUrea Kinetic\nALP\nSGOT\nSGPT\nUric Acid\nHDL Direct\nLDL Direct\n\nINFORMATION\nEVERY SINGLE REAGENTS HAS A DIFFRENCE PRICE\n1 PACK SINGLE PRICE.", "price": 1130.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "ALP", "GGT", "SGOT", "SGPT", "board", "tests", "CK MB", "CK NAC", "Glucose", "Calcium", "Amylase", "Uric Acid", "Creatinine", "LDL Direct", "HDL Direct", "Cholesterol", "INFORMATION", "ICHEM PRIME", "KITS Albumin", "zero wastage", "Urea Kinetic", "Easy inventory", "TURBOCHEM PRIME", "DIFFRENCE PRICE", "Billirubin total", "Bilirubin Direct", "Guaranteed number", "1 PACK SINGLE PRICE", "SYSTEM PACK REAGENTS", "EVERY SINGLE REAGENTS", "calibaration stability", "LDH L Magnesium Phosphorus Protein Triglycerides" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 135, "imageuri": "https://productimages.withfloats.com/actual/659bd01cfb723c4b5f289087.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/659bd01cfb723c4b5f289087.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-01-08T10:36:10.511Z", "updatedon": "2024-01-08T10:36:10.511Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//ichem-prime-system-pack-reagents-for-turbochem-prime/135", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "cpc", "category": "BiochemistryReagents", "tags": [ "#BiochemistryReagents", "#LabReagents", "#ResearchMaterials", "#BiochemicalAnalysis", "#DiagnosticReagents", "#BiomedicalResearch", "#BiotechSolutions", "#ChemicalAnalysis", "#LaboratoryScience", "#ResearchAndDevelopment", "#ClinicalChemistry", "#Bioreagents", "#LifeScience", "#ChemicalSolutions", "#BiochemicalTesting" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false }, { "_id": "659bbfb69bb0be169c7f794d", "fptag": "RAJBIOSISPVTLTD", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Accu-Chek® Active blood glucose meter ", "description": "Accu-Chek® Active blood glucose meter\nPersonalised Diabetes Coaching Accurate, no coding, easy\nItem Description\nThe Accu-Chek Active blood glucose meter packs many powerful features into a smaller size. No coding reduces handling steps, see test result averages up to 90 days, get alerts if your test strips are expired or if you’ve underdosed, re-dose within 10 seconds, set pre-and post-meal reminders to test, and more.\nBenefits and Features\naccurate:\n\nAccurate1 blood glucose measurement\neasy: \n\nNo coding for even easier blood glucose monitoring\neasy-to-read display (new typeface)\nintuitive handling with just 2 buttons\n safe:\n\nUnderdose detection\nvisual double check\n10 seconds re-dose option\n clever:\n\nPre- and postmeal markers\npostprandial reminder\n7,14,30 or now 90 day test averages\nUSB interface for data transfer\n Remark:\n\nPrevious Accu-Chek Active meter generations will be upgraded to no coding via black activation chip . Know more>>\n\n1The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014).\n\nAdditional specifications Meter type : \nAccu-Chek Active meter (Model GB)\n\n Catalogue no. / Serial no. : \nSee type plate on the back of the meter\n\n Test principle : \nDetermination of glucose in fresh capillary blood by reflectance photometry.\n\nBlood glucose values can be tested in whole blood or plasma.\n\nThe meter displays blood glucose values corresponding to those in plasma.\n\n Measuring interval : \n10-600 mg/dL\n\n Blood volume : \n1-2 μl\n\n Measuring time : \nTest strip in the meter: approx. 5 seconds\n\nTest strip outside the meter: approx. 08 seconds\n\n Power supply : \n1 battery (type CR2032)\n\n Battery life : \napprox. 1000 tests or approx. 1 year\n\n Automatic power-off : \nafter 30 or 90 seconds depending on operating status\n\n Memory : \n500 test results with time and date, as well as 7, 14, 30 and 90 days averages\n\n Temperature : \nDuring testing: +8 to +42°C\n\nDuring storage without battery: -25 to +70°C\n\nDuring storage with battery: -20 to +50°C\n\n Atmospheric humidity : \nDuring testing: up to 85% relative humidity\n\nDuring testing: up to 93% relative humidity\n\n Altitude: \nSea level to 4000 m\n\n Dimensions : \n97.8 x 46.8 x 19.1 mm\n\n Weight : \nWithout battery: approx. 46 g\n\nWith battery: approx. 50 g\n\n Display : \n96-segment liquid crystal display (LCD)\n\n Interface : \nUSB (Micro B)\n\n Safety class : \nIII\n\n Electromagnetic compatibility : \nThe Accu-Chek Active meter meets the electromagnetic immunity requirements and the electromagnetic emissions requirements as per EN 61326-2-6 and EN ISO 15197 Annex A.\n\nThe chosen basis for electrostatic discharge immunity testing was basic standard IEC 61000-4-2.\n\n Performance analysis : \nCalibration and traceability: The performance data for the Accu-Chek Active bGM system was calibrated using venous blood containing various glucose concentrations. Reference values are obtained using the hexokinase method, which is calibrated using the ID-GCMS method.\n\n Accuracy performance : \nThe Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014).\n\nHow to use Accu-Chek Active blood glucose meter\nTesting your blood glucose is an essential part of managing diabetes. The Accu-Chek Active blood glucose meter can help to make it convenient by giving you fast, hassle-free, and accurate results in 4 simple steps.\n\nInsert the glucose test strip\nPrick your finger with the lancet to draw out a blood drop.\nCarefully touch the blood drop onto the green field of the test strip.\nRead the blood glucose result.", "price": 980.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "°C", "30", "50°", "IEC", "LCD", "free", "fast", "date", "back", "file", "basis", "up to", "finger", "lancet", "Weight", "Memory", "1 year", "600 mg", "plasma", "Remark", "alerts", "coding", "1-2 μl", "19.1 mm", "storage", "Micro B", "Model GB", "Altitude", "Benefits", "2 buttons", "Sea level", "5 seconds", "Serial no", "Catalogue", "1 battery", "blood drop", "type plate", "1000 tests", "90 seconds", "test strips", "type CR2032", "test result", "green field", "Calibration", "Temperature", "Safety class", "Battery life", "smaller size", "50 g Display", "traceability", "venous blood", "Blood volume", "new typeface", "data transfer", "Determination", "USB interface", "4 simple steps", "ID-GCMS method", "Measuring time", "basic standard", "essential part", "handling steps", "meal reminders", "postmeal markers", "Reference values", "operating status", "90 days averages", "Item Description", "performance data", "accurate results", "4000 m Dimensions", "hexokinase method", "glucose test strip", "Measuring interval", "intuitive handling", "Automatic power-off", "Atmospheric humidity", "Blood glucose values", "Accuracy performance", "90 day test averages", "blood glucose result", "Performance analysis", "meter Test principle", "black activation chip", "fresh capillary blood", "EN ISO 15197 Annex A.", "85% relative humidity", "93% relative humidity", "postprandial reminder", "many powerful features", "reflectance photometry", "08 seconds Power supply", "10 seconds re-dose option", "The Accu-Chek Active meter", "Electromagnetic compatibility", "various glucose concentrations", "Personalised Diabetes Coaching", "easier blood glucose monitoring", "The Accu-Chek Active bGM system", "96-segment liquid crystal display", "DIN EN ISO 15197:2013 requirements", "Accurate1 blood glucose measurement", "Additional specifications Meter type", "electromagnetic immunity requirements", "Accu-Chek® Active blood glucose meter", "electromagnetic emissions requirements", "Underdose detection visual double check", "electrostatic discharge immunity testing", "The Accu-Chek Active blood glucose meter", "Previous Accu-Chek Active meter generations" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 132, "imageuri": "https://productimages.withfloats.com/actual/659bbfb7945fbef921fe6c48.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/659bbfb7945fbef921fe6c48.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-01-08T09:26:14.799Z", "updatedon": "2024-01-08T09:26:14.799Z", "buyonlinelink": null, "producturl": "https://WWW.RAJBIOSIS.IN//accu-chek-active-blood-glucose-meter-/132", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "Roche", "category": "Glucometer", "tags": [ "#Glucometer", "#BloodGlucoseMonitoring", "#DiabetesCare", "#BloodSugarMeter", "#DiabetesManagement", "#HealthTech", "#MedicalDevices", "#DiabetesAwareness", "#HealthAndWellness", "#DigitalHealth", "#DiabeticCare", "#SelfMonitoring", "#BloodSugarTest", "#GlucoseMeter", "#HealthTracking" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.001, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
net weight?

Still searching for
net weight?

Chat with us