Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "66337a27c1886b1a14f0bc13",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "AGAPPE Mispa Chem Dx Auto Dry Biochemistry Analyzer",
"description": "Overview\nA fully automated POC Auto Dry Biochemistry Analyzer called Mispa Chem Dx, With Just 3 to 4 drops (100ul) of whole blood to test up to 19 General and Special chemistry tests in less than 12 minutes. Mispa Chem Dx works on absorption spectroscopy where a change in absorbance is detected by an absorption spectrum and an algorithm is used to calculate the end concentration of the sample in the reagent dry disc. The reagent disc consists of lyophilized reagent beads, diluent, and calibration details in the QR code. The reagent disc contains an intelligent internal quality control system IQC which continuously monitors the disc function to ensure reaction stability and optimal disc performance, IQC is the engine that drives the Mispa Chem Dx accurately and precisely\n\n\nLow Sample Consumption\nEasy to Use\nMaintenance Free\nAccurate Result\nDisposable reagent disc\nSample volume: 100µl \nTesting time: 12 minutes / sample \nTemperature: 37°C ± 0.3°C \nResolution: 0.001Abs Absorbance: 0-3.0Abs \nSample type: Heparinized whole blood, serum, plasma (heparin)\nQC&Calibration: IQC (Intelligent Quality Control/Calibration) \nWork condition: Temperature:10-30°C Humidity: 30%-70%\nTesting method: End point, kinetic, fixed time, turbidmetry etc \nLight source: 12V/20W, Halogen tungsten lamp with life span over 2500 hours \nPower supply: AC 100V-240V, 50-60Hz \nDisplay: Android 7.0 inch 800*480, multi-point capacitive touch screen \nStorage: 500,000 results \nPrinter: Built-in thermal printer Interface: 4 USB ports, 1 LAN port \nDimension: 315*375*475mm. 4.2kg(N.W.), 7kg(G.W.)",
"price": 375000.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"0.",
"37",
"7kg",
"12V",
"IQC",
"G.W.",
"240V",
"less",
"N.W.",
"100µ",
"blood",
"475mm",
"serum",
"plasma",
"change",
"engine",
"QR code",
"diluent",
"AC 100V",
"heparin",
"kinetic",
"life span",
"End point",
"algorithm",
"12 minutes",
"fixed time",
"Resolution",
"19 General",
"absorbance",
"4 USB ports",
"Sample type",
"turbidmetry",
"Light source",
"Testing time",
"3 to 4 drops",
"Sample volume",
"disc function",
"QC&Calibration",
"Work condition",
"Accurate Result",
"Android 7.0 inch",
"Maintenance Free",
"reagent dry disc",
"end concentration",
"reaction stability",
"sample Temperature",
"calibration details",
"absorption spectrum",
"1 LAN port Dimension",
"Halogen tungsten lamp",
"Low Sample Consumption",
"Disposable reagent disc",
"2500 hours Power supply",
"500,000 results Printer",
"Special chemistry tests",
"absorption spectroscopy",
"optimal disc performance",
"lyophilized reagent beads",
"thermal printer Interface",
"Intelligent Quality Control",
"POC Auto Dry Biochemistry Analyzer",
"intelligent internal quality control system",
"multi-point capacitive touch screen Storage",
"AGAPPE Mispa Chem Dx Auto Dry Biochemistry Analyzer Overview"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 336,
"imageuri": "https://productimages.withfloats.com/actual/66337a2ae837fe0918be91c5.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/66337a2ae837fe0918be91c5.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-05-02T11:33:59.219Z",
"updatedon": "2024-05-02T11:33:59.219Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN/products/agappe-mispa-chem-dx-auto-dry-biochemistry-analyzer/336",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "AGAPPE",
"category": "Biochemistry Analyzer",
"tags": [
"#ChemicalTesting",
"BiochemistryAnalyzer",
"#LabTestingSolutions",
"#LabMedicine",
"#ClinicalChemistry",
"#MedicalLabInnovation",
"#BiochemicalAnalysis",
"#LabTesting",
"#ChemicalAnalysisTech",
"#HealthcareInnovation",
"#MedicalDiagnosis",
"#LabQualityAssurance",
"#LabTech",
"#ChemistryLab",
"#ClinicalTesting",
"#MedicalLabTesting",
"#HealthcareTech",
"#HealthTechAdvancements",
"#DiagnosticTechnology",
"#LabAnalysis",
"#BiochemicalMarkers",
"#LabResultsMatter",
"#DiagnosticTests",
"#LabDataAnalysis",
"#ClinicalDiagnosis",
"#MedicalInnovation",
"#DiagnosticsInsights",
"#BiochemistryLab",
"#LaboratoryScience",
"#BiochemistryLabTech",
"#HealthcareDiagnosis",
"#HealthTech",
"#PrecisionDiagnostic",
"#LabScience",
"#Biomarkers",
"#MedicalDetection",
"#MedicalTesting",
"#MedicalLab",
"#LabExcellence",
"#LabAccuracy",
"#ChemicalAnalysis",
"#HealthcareScience",
""
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "660e7d0704529c0aa82df157",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Typhoid Rapid Test ",
"description": "TYPHOID RAPID TEST KIT\nTYPHOID tests diagnose the non-structural protein of the dengue virus. The protein that is veiled into the blood of a patient diagnosed with dengue infection. Through this test, the keen phase of the virus infection can be detected. This sensitive test can show the infection of 0-7 days. If you have attained this stage, then this test is not considered valid. Positive NS1 result shows the presence of dengue infection in a human body but does not provide the entire information. Otherwise, serotype information is not necessary for the care of the infected person, but still this information matters.\n\nSpecimen Serum or blood\n\nExplanation of the test result\n• A positive result shows typhoid virus infection without serotype data. • A negative NS1 test does not confirms any infection. People with negative results are tested in order to see the occurrence of dengue IgM antibodies. These test kits are available commercially. Various laboratories and public health care centers utilize this DENGUE NS1 Rapid Test Kit.",
"price": 1250.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"stage",
"blood",
"order",
"People",
"patient",
"0-7 days",
"presence",
"test kits",
"human body",
"keen phase",
"occurrence",
"test result",
"Explanation",
"dengue virus",
"TYPHOID tests",
"serotype data",
"sensitive test",
"Specimen Serum",
"infected person",
"positive result",
"dengue infection",
"negative results",
"negative NS1 test",
"entire information",
"Positive NS1 result",
"Various laboratories",
"serotype information",
"dengue IgM antibodies",
"TYPHOID RAPID TEST KIT",
"non-structural protein",
"typhoid virus infection",
"DENGUE NS1 Rapid Test Kit",
"public health care centers"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 173,
"imageuri": "https://productimages.withfloats.com/actual/660e7d0c57625921b873a815.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/660e7d0c57625921b873a815.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-04-04T10:12:23.732Z",
"updatedon": "2024-04-04T10:12:23.732Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//typhoid-rapid-test-/173",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Avecon",
"category": "Rapid Test",
"tags": [
"#RapidTestKit",
"#TestKitResults",
"#HealthCheckup",
"#DiagnosticTesting",
"#QuickTesting",
"#TestKitResultsMatter",
"#HealthScreening",
"#HealthCheck",
"#QuickHealthScreening",
"#MedicalTesting",
"#MedicalDiagnosis",
"#MedicalDiagnosisTools",
"#QuickDiagnosis",
"#DiagnosticSolutions",
"#PointOfCareSolutions",
"#PointOfCareTesting",
"#HealthWellness",
"#InnovativeTesting",
"#HealthcareTech",
"#RapidDetection",
"#HealthAwareness",
"#MedicalDevices",
"#LabTech",
"#RapidScreening",
"#RapidResults",
"#HealthcareInnovation",
"#MedicalDevicesTech",
"#DiagnosticInnovation",
"#TestAccuracy",
"#DiagnosticAccuracy",
"#TestKitTechnology",
"#MedicalScreening",
"#HealthWellnessKit",
"#HealthTech",
"#RapidResponse",
"#RapidHealthCheck",
"#LabTesting",
"#HomeTesting",
"#AtHomeDiagnostics",
""
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "660e7b6c64553f1ad0f56b7c",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "DENGUE NS1 ",
"description": "DENGUE NS1 Rapid Test Kit\nNS1 tests diagnose the non-structural protein of the dengue virus. The protein that is veiled into the blood of a patient diagnosed with dengue infection. Through this test, the keen phase of the virus infection can be detected. This sensitive test can show the infection of 0-7 days. If you have attained this stage, then this test is not considered valid.\n\nPositive NS1 result shows the presence of dengue infection in a human body but does not provide the entire information. Otherwise, serotype information is not necessary for the care of the infected person, but still this information matters.\n\nSpecimen\nSerum or blood\nExplanation of the test result\nA positive result shows dengue virus infection without serotype data.\nA negative NS1 test does not confirms any infection. People with negative results are tested in order to see the occurrence of dengue IgM antibodies.\nThese test kits are available commercially. Various laboratories and public health care centers utilize this DENGUE NS1 Rapid Test Kit.",
"price": 850.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"Serum",
"stage",
"blood",
"order",
"People",
"patient",
"Specimen",
"presence",
"0-7 days",
"NS1 tests",
"test kits",
"human body",
"keen phase",
"occurrence",
"Explanation",
"test result",
"serotype data",
"sensitive test",
"positive result",
"infected person",
"negative results",
"dengue infection",
"negative NS1 test",
"entire information",
"Positive NS1 result",
"serotype information",
"Various laboratories",
"dengue IgM antibodies",
"non-structural protein",
"dengue virus infection",
"DENGUE NS1 Rapid Test Kit",
"public health care centers"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 171,
"imageuri": "https://productimages.withfloats.com/actual/660e7b7257625921b873a5bf.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/660e7b7257625921b873a5bf.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-04-04T10:05:32.89Z",
"updatedon": "2024-04-04T10:05:32.89Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//dengue-ns1-/171",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Avecon",
"category": "Rapid Test",
"tags": [
"#RapidTestKit",
"#TestKitResults",
"#HealthCheckup",
"#DiagnosticTesting",
"#QuickTesting",
"#TestKitResultsMatter",
"#HealthScreening",
"#HealthCheck",
"#QuickHealthScreening",
"#MedicalTesting",
"#MedicalDiagnosis",
"#MedicalDiagnosisTools",
"#QuickDiagnosis",
"#DiagnosticSolutions",
"#PointOfCareSolutions",
"#PointOfCareTesting",
"#HealthWellness",
"#InnovativeTesting",
"#HealthcareTech",
"#RapidDetection",
"#HealthAwareness",
"#MedicalDevices",
"#LabTech",
"#RapidScreening",
"#RapidResults",
"#HealthcareInnovation",
"#MedicalDevicesTech",
"#DiagnosticInnovation",
"#TestAccuracy",
"#DiagnosticAccuracy",
"#TestKitTechnology",
"#MedicalScreening",
"#HealthWellnessKit",
"#HealthTech",
"#RapidResponse",
"#RapidHealthCheck",
"#LabTesting",
"#HomeTesting",
"#AtHomeDiagnostics",
""
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "660e7894b7244c1b144a96eb",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "HIV 1 AND 2 TRILINE ",
"description": "HIV rapid test kit procedure\nHIV testing or screening is done to get to know the presence of the virus in the human body. There are a number of tests that can be done to check your blood if you are infected with the HIV virus. Not all tests can detect this virus in your body as it takes time for the virus to grow in your body.\n\nThe consequence of HIV testing:\nIf your body has the virus and it gets detected at an early stage, then the treatment can be started and the growth of that virus can be stopped right there.\n\nWho should get this test done?\nNew sexual partners should get this test done before having sex in order to keep them away from this disease.\nIn the United States, people between the age of 13 and 64, need to be tested for this virus once.\nNowadays the awareness of this test is at high and thus the usage of HIV rapid test kit is increasing at a high speed. This kit can offer you results within 5 to 15 minutes and the results are 99% accurate. Medical practitioners totally rely on this kit to detect this virus.",
"price": 3500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"time",
"order",
"blood",
"tests",
"usage",
"people",
"growth",
"number",
"results",
"disease",
"presence",
"screening",
"HIV virus",
"treatment",
"awareness",
"2 TRILINE",
"human body",
"high speed",
"consequence",
"early stage",
"HIV testing",
"United States",
"5 to 15 minutes",
"New sexual partners",
"Medical practitioners",
"HIV rapid test kit procedure"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 168,
"imageuri": "https://productimages.withfloats.com/actual/660e789adb3d9ef52c102f08.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/660e789adb3d9ef52c102f08.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-04-04T09:53:24.859Z",
"updatedon": "2024-04-04T09:53:24.859Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//hiv-1-and-2-triline-/168",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Avecon",
"category": "Rapid Test",
"tags": [
"#RapidTestKit",
"#TestKitResults",
"#HealthCheckup",
"#DiagnosticTesting",
"#QuickTesting",
"#TestKitResultsMatter",
"#HealthScreening",
"#HealthCheck",
"#QuickHealthScreening",
"#MedicalTesting",
"#MedicalDiagnosis",
"#MedicalDiagnosisTools",
"#QuickDiagnosis",
"#DiagnosticSolutions",
"#PointOfCareSolutions",
"#PointOfCareTesting",
"#HealthWellness",
"#InnovativeTesting",
"#HealthcareTech",
"#RapidDetection",
"#HealthAwareness",
"#MedicalDevices",
"#LabTech",
"#RapidScreening",
"#RapidResults",
"#HealthcareInnovation",
"#MedicalDevicesTech",
"#DiagnosticInnovation",
"#TestAccuracy",
"#DiagnosticAccuracy",
"#TestKitTechnology",
"#MedicalScreening",
"#HealthWellnessKit",
"#HealthTech",
"#RapidResponse",
"#RapidHealthCheck",
"#LabTesting",
"#HomeTesting",
"#AtHomeDiagnostics",
""
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "659bd0d67d5b260c20c1dd23",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "CHEMISTRY CALIBRATOR AND CHEMISTRY CONTROLS REAGENTS",
"description": "CHEMISTRY CALIBRATOR AND CHEMISTRY CONTROLS\nChemistry calibrators cover commonly used clinical chemistry tests.\n\nTwo clinically significant Control levels with method and instrument specific target values and ranges are available\n\nFeatures & Benefits\nHuman based serum – lyophilised for enhanced stability\nStable to expiry date at 2°C – 8°C\nReconstituted stability of up to 7 days at 2°C – 8°C or 4 weeks at -20°C\n",
"price": 800.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"2°C",
"8°C",
"date",
"expiry",
"ranges",
"method",
"4 weeks",
"Benefits",
"Features",
"REAGENTS",
"up to 7 days",
"Human based serum",
"enhanced stability",
"CHEMISTRY CONTROLS",
"CHEMISTRY CALIBRATOR",
"Reconstituted stability",
"clinical chemistry tests",
"instrument specific target values",
"Two clinically significant Control levels"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 136,
"imageuri": "https://productimages.withfloats.com/actual/659bd0d9e0105bf33f28eb67.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/659bd0d9e0105bf33f28eb67.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-01-08T10:39:18.777Z",
"updatedon": "2024-01-08T10:39:18.777Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//chemistry-calibrator-and-chemistry-controls-reagents/136",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "cpc",
"category": "BiochemistryReagents",
"tags": [
"#BiochemistryReagents",
"#LabReagents",
"#ResearchMaterials",
"#BiochemicalAnalysis",
"#DiagnosticReagents",
"#BiomedicalResearch",
"#BiotechSolutions",
"#ChemicalAnalysis",
"#LaboratoryScience",
"#ResearchAndDevelopment",
"#ClinicalChemistry",
"#Bioreagents",
"#LifeScience",
"#ChemicalSolutions",
"#BiochemicalTesting"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "659bbfb69bb0be169c7f794d",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Accu-Chek® Active blood glucose meter ",
"description": "Accu-Chek® Active blood glucose meter\nPersonalised Diabetes Coaching Accurate, no coding, easy\nItem Description\nThe Accu-Chek Active blood glucose meter packs many powerful features into a smaller size. No coding reduces handling steps, see test result averages up to 90 days, get alerts if your test strips are expired or if you’ve underdosed, re-dose within 10 seconds, set pre-and post-meal reminders to test, and more.\nBenefits and Features\naccurate:\n\nAccurate1 blood glucose measurement\neasy: \n\nNo coding for even easier blood glucose monitoring\neasy-to-read display (new typeface)\nintuitive handling with just 2 buttons\n safe:\n\nUnderdose detection\nvisual double check\n10 seconds re-dose option\n clever:\n\nPre- and postmeal markers\npostprandial reminder\n7,14,30 or now 90 day test averages\nUSB interface for data transfer\n Remark:\n\nPrevious Accu-Chek Active meter generations will be upgraded to no coding via black activation chip . Know more>>\n\n1The Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014).\n\nAdditional specifications Meter type : \nAccu-Chek Active meter (Model GB)\n\n Catalogue no. / Serial no. : \nSee type plate on the back of the meter\n\n Test principle : \nDetermination of glucose in fresh capillary blood by reflectance photometry.\n\nBlood glucose values can be tested in whole blood or plasma.\n\nThe meter displays blood glucose values corresponding to those in plasma.\n\n Measuring interval : \n10-600 mg/dL\n\n Blood volume : \n1-2 μl\n\n Measuring time : \nTest strip in the meter: approx. 5 seconds\n\nTest strip outside the meter: approx. 08 seconds\n\n Power supply : \n1 battery (type CR2032)\n\n Battery life : \napprox. 1000 tests or approx. 1 year\n\n Automatic power-off : \nafter 30 or 90 seconds depending on operating status\n\n Memory : \n500 test results with time and date, as well as 7, 14, 30 and 90 days averages\n\n Temperature : \nDuring testing: +8 to +42°C\n\nDuring storage without battery: -25 to +70°C\n\nDuring storage with battery: -20 to +50°C\n\n Atmospheric humidity : \nDuring testing: up to 85% relative humidity\n\nDuring testing: up to 93% relative humidity\n\n Altitude: \nSea level to 4000 m\n\n Dimensions : \n97.8 x 46.8 x 19.1 mm\n\n Weight : \nWithout battery: approx. 46 g\n\nWith battery: approx. 50 g\n\n Display : \n96-segment liquid crystal display (LCD)\n\n Interface : \nUSB (Micro B)\n\n Safety class : \nIII\n\n Electromagnetic compatibility : \nThe Accu-Chek Active meter meets the electromagnetic immunity requirements and the electromagnetic emissions requirements as per EN 61326-2-6 and EN ISO 15197 Annex A.\n\nThe chosen basis for electrostatic discharge immunity testing was basic standard IEC 61000-4-2.\n\n Performance analysis : \nCalibration and traceability: The performance data for the Accu-Chek Active bGM system was calibrated using venous blood containing various glucose concentrations. Reference values are obtained using the hexokinase method, which is calibrated using the ID-GCMS method.\n\n Accuracy performance : \nThe Accu-Chek Active bGM system meets the DIN EN ISO 15197:2013 requirements (data on file, 2014).\n\nHow to use Accu-Chek Active blood glucose meter\nTesting your blood glucose is an essential part of managing diabetes. The Accu-Chek Active blood glucose meter can help to make it convenient by giving you fast, hassle-free, and accurate results in 4 simple steps.\n\nInsert the glucose test strip\nPrick your finger with the lancet to draw out a blood drop.\nCarefully touch the blood drop onto the green field of the test strip.\nRead the blood glucose result.",
"price": 980.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"°C",
"30",
"50°",
"IEC",
"LCD",
"free",
"fast",
"date",
"back",
"file",
"basis",
"up to",
"finger",
"lancet",
"Weight",
"Memory",
"1 year",
"600 mg",
"plasma",
"Remark",
"alerts",
"coding",
"1-2 μl",
"19.1 mm",
"storage",
"Micro B",
"Model GB",
"Altitude",
"Benefits",
"2 buttons",
"Sea level",
"5 seconds",
"Serial no",
"Catalogue",
"1 battery",
"blood drop",
"type plate",
"1000 tests",
"90 seconds",
"test strips",
"type CR2032",
"test result",
"green field",
"Calibration",
"Temperature",
"Safety class",
"Battery life",
"smaller size",
"50 g Display",
"traceability",
"venous blood",
"Blood volume",
"new typeface",
"data transfer",
"Determination",
"USB interface",
"4 simple steps",
"ID-GCMS method",
"Measuring time",
"basic standard",
"essential part",
"handling steps",
"meal reminders",
"postmeal markers",
"Reference values",
"operating status",
"90 days averages",
"Item Description",
"performance data",
"accurate results",
"4000 m Dimensions",
"hexokinase method",
"glucose test strip",
"Measuring interval",
"intuitive handling",
"Automatic power-off",
"Atmospheric humidity",
"Blood glucose values",
"Accuracy performance",
"90 day test averages",
"blood glucose result",
"Performance analysis",
"meter Test principle",
"black activation chip",
"fresh capillary blood",
"EN ISO 15197 Annex A.",
"85% relative humidity",
"93% relative humidity",
"postprandial reminder",
"many powerful features",
"reflectance photometry",
"08 seconds Power supply",
"10 seconds re-dose option",
"The Accu-Chek Active meter",
"Electromagnetic compatibility",
"various glucose concentrations",
"Personalised Diabetes Coaching",
"easier blood glucose monitoring",
"The Accu-Chek Active bGM system",
"96-segment liquid crystal display",
"DIN EN ISO 15197:2013 requirements",
"Accurate1 blood glucose measurement",
"Additional specifications Meter type",
"electromagnetic immunity requirements",
"Accu-Chek® Active blood glucose meter",
"electromagnetic emissions requirements",
"Underdose detection visual double check",
"electrostatic discharge immunity testing",
"The Accu-Chek Active blood glucose meter",
"Previous Accu-Chek Active meter generations"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 132,
"imageuri": "https://productimages.withfloats.com/actual/659bbfb7945fbef921fe6c48.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/659bbfb7945fbef921fe6c48.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-01-08T09:26:14.799Z",
"updatedon": "2024-01-08T09:26:14.799Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//accu-chek-active-blood-glucose-meter-/132",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Roche",
"category": "Glucometer",
"tags": [
"#Glucometer",
"#BloodGlucoseMonitoring",
"#DiabetesCare",
"#BloodSugarMeter",
"#DiabetesManagement",
"#HealthTech",
"#MedicalDevices",
"#DiabetesAwareness",
"#HealthAndWellness",
"#DigitalHealth",
"#DiabeticCare",
"#SelfMonitoring",
"#BloodSugarTest",
"#GlucoseMeter",
"#HealthTracking"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "659b87389bb0be169c7f786f",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "ADVIA 2400 Clinical Chemistry Analyser System",
"description": "ADVIA 2400 Chemistry System The right balance of speed and efficiency \nThe ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers:\nHigh throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads\nRapid, consistent, 2-second cycle time for faster tube speed and test throughput\nUser-defined automatic repeat, dilution, and reflex testing\nLarge onboard reagent capacity and optional concentrated reagents help to minimize intervention demands\nRefrigerated onboard storage of controls and reagents for extended stability and increased productivity\nAutomation-ready design: no additional hardware required\nFeatures & Benefits\nThe ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing.\n\nThe ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories \n\nSuperior Speed and Productivity\n\nThroughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads\nRapid, consistent, 2-second cycle time\nThroughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample\nAutomatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing\nAutomation-ready\n\nPoint-in-space aspiration enables connectivity to a track.\nRedundant sample loading provides built-in backup and easy handling of non-routine samples.\nDirect sampling from track prevents tubes being detained at an analyzer and reduces aliquoting.\nMinimal Need for Operator Intervention\n\nMinimal-maintenance ISEs\nLarge onboard reagent capacity and optional concentrated reagents for fewer interruptions\nNo-maintenance, 37°C incubation oil bath\nAuto-calibration and auto-QC from refrigerated onboard calibrators and controls\nMicrovolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity.\nRemote diagnostics and Inter-Laboratory Quality Control (ILQC) options\nExceptional Reliability\n\nSample integrity check for icterus, hemolysis, and lipemia\nSample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection\nAdvances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity",
"price": 445000.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"TDM",
"DAT",
"menu",
"hour",
"HbA1c",
"track",
"backup",
"600 ISE",
"methods",
"general",
"auto-QC",
"icterus",
"lipemia",
"Benefits",
"Features",
"controls",
"dilution",
"analyzer",
"Advances",
"reduction",
"200 tubes",
"hemolysis",
"cystatin C",
"2400 tests",
"to 60 days",
"aliquoting",
"efficiency",
"calibrators",
"Minimal Need",
"32,000 tests",
"Sample probe",
"connectivity",
"ILQC) options",
"right balance",
"interferences",
"abuse testing",
"walkaway time",
"easy handling",
"00 photometric",
"reflex testing",
"Superior Speed",
"assay linearity",
"Direct sampling",
"test throughput",
"routine samples",
"routine testing",
"three ISE tests",
"turnaround time",
"onboard storage",
"High throughput",
"heavy workloads",
"Auto-calibration",
"crash protection",
"maximum capacity",
"space aspiration",
"reagent stability",
"faster tube speed",
"therapeutic drugs",
"heaviest workloads",
"Remote diagnostics",
"CardioPhase® hsCRP",
"extended stability",
"additional hardware",
"productivity levels",
"fewer interruptions",
"demanding workloads",
"intervention demands",
"liquid-level sensing",
"calibration frequency",
"Operator Intervention",
"specialty chemistries",
"Sample integrity check",
"nine photometric tests",
"Interesting new assays",
"Microvolume technology",
"short-sample detection",
"Exceptional Reliability",
"Automation-ready design",
"Minimal-maintenance ISEs",
"high-volume laboratories",
"37°C incubation oil bath",
"Redundant sample loading",
"high turnaround-time goals",
"therapeutic drug monitoring",
"specific protein measurement",
"automated sample pretreatment",
"User-defined automatic repeat",
"automatic clot/clog detection",
"efficient automation-readiness",
"Large onboard reagent capacity",
"optional concentrated reagents",
"The ADVIA 2400 Chemistry System",
"Inter-Laboratory Quality Control",
"high turnaround-time (TAT) goals",
"rapid, 2-second probe cycle time",
"Automatic Sample Retain technology",
"Rapid, consistent, 2-second cycle time",
"The ADVIA 2400 Clinical Chemistry System",
"The ADVIA® 2400 Clinical Chemistry System",
"ADVIA 2400 Clinical Chemistry Analyser System"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 103,
"imageuri": "https://productimages.withfloats.com/actual/659b8739a60e6e828d30e024.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/659b8739a60e6e828d30e024.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-01-08T05:25:12.036Z",
"updatedon": "2024-01-08T05:25:12.036Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//advia-2400-clinical-chemistry-analyser-system/103",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Siemens",
"category": "Clinical Chemistry",
"tags": [
"#ClinicalChemistry",
"#LabTests",
"#DiagnosticTesting",
"#MedicalTechnology",
"#ClinicalAnalysis",
"#HealthcareTech",
"#DiagnosticChemistry",
"#LaboratoryScience",
"#ClinicalLaboratory",
"#HealthTech",
"#BiochemicalAnalysis",
"#ChemicalTests",
"#Biochemistry",
"#ClinicalDiagnosis",
"#MedicalLaboratory"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "65927f82545ff1187c886bad",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "I Chroma II A compact and easy-to-use fluorescence based POCT immunoassay analyzer ",
"description": "ichroma IIA compact and easy-to-use, fluorescence based POCT immunoassay analyzer, Point of care Analyzer\nichroma II is a compact, easy-to-use diagnostic immuno-analyzer to measure the presence of various biomarkers for cardiac, cancer, hormones, infectious diseases, autoimmune diseases, and metabolic diseases.\n\n\niChroma II is an advanced immunoassay reader in our SwifTest range of POC devices. It utilizes the latest immuno-fluorescence technology and provides a simple, fast and reliable method to diagnose a patient’s condition or monitor a treatment response.\n\nIChroma II provides results correlating with the laboratory along with all the benefits offered by point-of-care like quick test time, portability, low running costs & user friendly operation making it an ideal choice for any laboratory. IChroma II can be useful for diagnosing conditions such as infection, diabetes, hormonal conditions, cardiovascular diseases, renal injury and cancers etc. in blood, serum, plasma, urine or other samples, in quantitative or semi-quantitative ways.\n\n iChroma is a registered trademark of Boditech Med Inc.\n\n\nIChroma II Features\nFully Portable Battery and/or AC power), Lightweight Reader\nHigh Throughput Patient Testing: 30 tests/hr\nWidest Test Menu on a Single Platform: 44 Parameters across 8 Therapeutic Test Profiles\nLarge Memory: 1000 Samples, 1000 QC & 100 IDs\nConvenient: 7” Colour Touch Screen, User-Friendly Interface\nSmart Calibration Chip: No Reagent Wastage & Calibration Failure\nInternal & External Quality Controls available\nLIS/HIS Compatible\nEnhanced Data Management & Connectivity: USB port/Ethernet/SD card slot\n\n\n",
"price": 67000.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"serum",
"blood",
"Point",
"urine",
"plasma",
"cancer",
"compact",
"cardiac",
"results",
"1000 QC",
"100 IDs",
"hormones",
"presence",
"benefits",
"Internal",
"diabetes",
"30 tests",
"AC power",
"infection",
"laboratory",
"portability",
"I Chroma II",
"ichroma IIA",
"POC devices",
"1000 Samples",
"renal injury",
"ideal choice",
"simple, fast",
"Connectivity",
"44 Parameters",
"other samples",
"care Analyzer",
"SwifTest range",
"quick test time",
"Reagent Wastage",
"Single Platform",
"reliable method",
"Boditech Med Inc",
"Widest Test Menu",
"low running costs",
"various biomarkers",
"LIS/HIS Compatible",
"metabolic diseases",
"treatment response",
"hormonal conditions",
"Calibration Failure",
"infectious diseases",
"IChroma II Features",
"autoimmune diseases",
"registered trademark",
"7” Colour Touch Screen",
"Smart Calibration Chip",
"Fully Portable Battery",
"semi-quantitative ways",
"cardiovascular diseases",
"user friendly operation",
"User-Friendly Interface",
"Enhanced Data Management",
"POCT immunoassay analyzer",
"External Quality Controls",
"diagnostic immuno-analyzer",
"advanced immunoassay reader",
"USB port/Ethernet/SD card slot",
"latest immuno-fluorescence technology",
"8 Therapeutic Test Profiles Large Memory",
"Lightweight Reader High Throughput Patient Testing"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 82,
"imageuri": "https://productimages.withfloats.com/actual/65927f84d5680f923376699e.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/65927f84d5680f923376699e.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-01-01T09:01:54.708Z",
"updatedon": "2024-01-01T09:01:54.708Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//i-chroma-ii-a-compact-and-easy-to-use-fluorescence-based-poct-immunoassay-analyzer-/82",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Boditech ichroma",
"category": "Immunoassay analyzer",
"tags": [
"#ImmunoassayAnalyzer",
"#DiagnosticTechnology",
"#LabInstrumentation",
"#MedicalDiagnosis",
"#HealthcareTech",
"#BiomedicalScience",
"#ClinicalLab",
"#DiagnosticEquipment",
"#MedicalDevices",
"#Immunodiagnostics",
"#LaboratoryTech",
"#DiagnosticsTech",
"#AssayAutomation",
"#HighThroughput",
"#BiomedicalTechnology",
"#MedicalInnovation",
"#HealthTech",
"#DiagnosticSolutions",
"#LabAutomation",
"#ClinicalPathology"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "66ec061aac0363ee7b838161",
"fptag": "RAJBIOSISPVTLTD",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Yumizen CA40 Semi-automated Clinical Chemistry Analyzer",
"description": "Yumizen CA40 Semi-automated Clinical Chemistry Analyzer:\nYumizen CA40 is a semi-automated Clinical Chemistry analyzer with facility to perform Chemistry, Immunoturbidimetry and Coagulation Tests (PT & APTT). It is an ideal solution for small laboratories with the facility to perform a wide range of biochemical tests.\n\nSpecification:-\nSemi-automated Clinical Chemistry analyzer with coagulation tests capacity (PT & APTT)\n8 incubation positions for chemistry tests and 5 positions for coagulation tests\n8-inch colored touch screen display\nTri-level Quality Control with Levey-Jennings chart\n6 filters with additional 2 open positions",
"price": 115000.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"6 filters",
"wide range",
"5 positions",
"ideal solution",
"chemistry tests",
"biochemical tests",
"small laboratories",
"Levey-Jennings chart",
"8 incubation positions",
"Tri-level Quality Control",
"coagulation tests capacity",
"additional 2 open positions",
"8-inch colored touch screen display",
"Yumizen CA40 Semi-automated Clinical Chemistry Analyzer"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 338,
"imageuri": "https://productimages.withfloats.com/actual/66ec061d574748dd80a31abb.jpeg",
"tileimageuri": "https://productimages.withfloats.com/tile/66ec061d574748dd80a31abb.jpeg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-09-19T11:08:10.266Z",
"updatedon": "2024-09-19T11:08:10.266Z",
"buyonlinelink": null,
"producturl": "https://WWW.RAJBIOSIS.IN//yumizen-ca40-semi-automated-clinical-chemistry-analyzer/338",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "Horiba",
"category": "Biochemistry Analyzer",
"tags": [
"#SemiAutoAnalyzer",
"#BiochemistrySolutions",
"#SemiAutoLabTech",
"#BiochemistryPrecision",
"#SemiAutoDiagnostics",
"#SmartBiochemistry",
"#EfficientBiochemistryTesting",
"#SemiAutoAnalyzerTech",
"#BiochemistryInnovation",
"#SemiAutoAccuracy"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "5d08ebb4edf0e25c3b8da5db",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.001,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}